REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

ISO 3036:2025 Board – Determination of puncture resistance using a pendulum device

$

115

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 16A: Specification for Drill-through Equipment

$

321.30

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 16A: Addendum 2

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 620: Design and Construction of Large, Welded, Low-Pressure Storage Tanks

$

847.35

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 620: Errata 1

$

0

BUY NOW

ISO 16890:2024

ISO 16890:2024 Air filters for general ventilation – Part 3: Determination of the gravimetric efficiency and the air flow resistance versus the mass of test dust captured

CDN $233.00

SKU: 668ede099822 Category:

Description

This document specifies the test equipment and the test methods used for measuring the gravimetric efficiency and resistance to air flow of air filter for general ventilation.

It is intended for use in conjunction with ISO 16890-1, ISO 16890-2 and ISO 16890-4.

The test method described in this document is applicable for air flow rates between 0,25 m3/s (900 m3/h, 530 ft3/min) and 1,5 m3/s (5 400 m3/h, 3 178 ft3/min), referring to a test rig with a nominal face area of 610 mm × 610 mm (24 in × 24 in).

This document refers to particulate air filter elements for general ventilation having an ePM1 efficiency less than or equal to 99 % and an ePM10 efficiency greater than 20 % when tested as per the procedures defined in the ISO 16890 series.

NOTE            The lower limit for this test procedure is set at a minimum ePM10 efficiency of 20 % since it is very difficult for a test filter element below this level to meet the statistical validity requirements of this procedure.

This document does not apply to filter elements used in portable room-air cleaners.

Edition

2

Published Date

2024-08-22

Status

PUBLISHED

Pages

22

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies the test equipment and the test methods used for measuring the gravimetric efficiency and resistance to air flow of air filter for general ventilation.

It is intended for use in conjunction with ISO 16890-1, ISO 16890-2 and ISO 16890-4.

The test method described in this document is applicable for air flow rates between 0,25 m3/s (900 m3/h, 530 ft3/min) and 1,5 m3/s (5 400 m3/h, 3 178 ft3/min), referring to a test rig with a nominal face area of 610 mm × 610 mm (24 in × 24 in).

This document refers to particulate air filter elements for general ventilation having an ePM1 efficiency less than or equal to 99 % and an ePM10 efficiency greater than 20 % when tested as per the procedures defined in the ISO 16890 series.

NOTE            The lower limit for this test procedure is set at a minimum ePM10 efficiency of 20 % since it is very difficult for a test filter element below this level to meet the statistical validity requirements of this procedure.

This document does not apply to filter elements used in portable room-air cleaners.

Previous Editions

Can’t find what you are looking for?

Please contact us at: