Search
×
FR

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-6 Chapter 6 – Density

$

204

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 560: Fired Heaters for General Refinery Services

$

721

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 64: Diverter Equipment Systems

$

324

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 17.10.1: Refrigerated Light Hydrocarbon Fluids – Measurement of Cargoes on Board LNG Carries

$

417

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-1: Testing Water-based Drilling Fluids

$

418

BUY NOW

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-12 Chapter 12 – Thermal Conductivity

$

214

BUY NOW

Placeholder headline

This is just a placeholder headline

API 16FI Frac Iron Guidelines and Requirements

$

129

BUY NOW

ISO 20289:2018

ISO 20289:2018 Surface chemical analysis – Total reflection X-ray fluorescence analysis of water

CDN $233.00

Description

ISO 20289:2018 provides a chemical method for technicians working with Total Reflection X-ray Fluorescence (TXRF) instrumentation to perform measurements of water samples, according to good practices, with a defined degree of accuracy and precision. Target users are identified among laboratories performing routine analysis of large numbers of samples, which also comply with ISO/IEC 17025.

ISO 20289:2018 specifies a method to determine the content of elements dissolved in water (for example, drinking water, surface water and ground water). Taking into account the specific and additionally occurring interferences, elements can also be determined in waste waters and eluates. Sampling, dilution and pre-concentration methods are not included in this document.

Elements that can be determined with the present method may change according to the X-ray source of the instrument. No health, safety or commercial aspects are considered herewith.

The working range depends on the matrix and the interferences encountered. In drinking water and relatively unpolluted waters, the limit of quantification lies between 0,001 mg/l and 0,01 mg/l for most of the elements. The working range typically covers concentrations between 0,001 mg/l and 10 mg/l, depending on the element and predefined requirements.

Annex B reports, for example, the complete validation of the method of TXRF analysis of water performed with instrumentation that has Mo as the X-ray source and uses Ga as the internal standard for calibration.

Quantification limits of most elements are affected by blank contamination and depend predominantly on the laboratory air-handling facilities available, on the purity of reagents and the cleanliness of labware.

Edition

1

Published Date

2018-03-15

Status

PUBLISHED

Pages

19

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 20289:2018 provides a chemical method for technicians working with Total Reflection X-ray Fluorescence (TXRF) instrumentation to perform measurements of water samples, according to good practices, with a defined degree of accuracy and precision. Target users are identified among laboratories performing routine analysis of large numbers of samples, which also comply with ISO/IEC 17025.

ISO 20289:2018 specifies a method to determine the content of elements dissolved in water (for example, drinking water, surface water and ground water). Taking into account the specific and additionally occurring interferences, elements can also be determined in waste waters and eluates. Sampling, dilution and pre-concentration methods are not included in this document.

Elements that can be determined with the present method may change according to the X-ray source of the instrument. No health, safety or commercial aspects are considered herewith.

The working range depends on the matrix and the interferences encountered. In drinking water and relatively unpolluted waters, the limit of quantification lies between 0,001 mg/l and 0,01 mg/l for most of the elements. The working range typically covers concentrations between 0,001 mg/l and 10 mg/l, depending on the element and predefined requirements.

Annex B reports, for example, the complete validation of the method of TXRF analysis of water performed with instrumentation that has Mo as the X-ray source and uses Ga as the internal standard for calibration.

Quantification limits of most elements are affected by blank contamination and depend predominantly on the laboratory air-handling facilities available, on the purity of reagents and the cleanliness of labware.

Previous Editions

Can’t find what you are looking for?

Please contact us at: