This document provides guidance on the requirements of ISO 11135 that apply when parametric release is used to release the product after exposure to the sterilization process. It provides a path for transition of existing cycles, as well as a path for the development and implementation of a parametric release specification for a new cycle. Additionally, it highlights the importance and interrelationship of other process factors, i.e. load configuration and equipment performance, which influence reproducibility of an ethylene oxide (EO) sterilization process.
NOTE For ease of reference, the numbering of clauses in this document corresponds to that in the normative parts of ISO 11135.
No additional guidance is offered for processes where the declaration of adequacy of the validated sterilization cycle includes a requirement for no growth in biological indicators (BIs) exposed to that process.
Edition
1
Published Date
2020-09-15
Status
PUBLISHED
Pages
17
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment

Abstract
This document provides guidance on the requirements of ISO 11135 that apply when parametric release is used to release the product after exposure to the sterilization process. It provides a path for transition of existing cycles, as well as a path for the development and implementation of a parametric release specification for a new cycle. Additionally, it highlights the importance and interrelationship of other process factors, i.e. load configuration and equipment performance, which influence reproducibility of an ethylene oxide (EO) sterilization process.
NOTE For ease of reference, the numbering of clauses in this document corresponds to that in the normative parts of ISO 11135.
No additional guidance is offered for processes where the declaration of adequacy of the validated sterilization cycle includes a requirement for no growth in biological indicators (BIs) exposed to that process.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-
ISO 22421:2021 Sterilization of health care products – Common requirements for sterilizers for terminal sterilization of medical devices in health care facilities
0 out of 5CDN $312.00 Add to cart -
ISO 11137:2020 Sterilization of health care products – Radiation – Part 4: Guidance on process control
0 out of 5CDN $351.00 Add to cart -
ISO 11139:2024 Sterilization of health care products – Vocabulary of terms used in sterilization and related equipment and process standards – Amendment 1: Amended and additional terms and definitions
0 out of 5CDN $32.00 Add to cart -
ISO 11737:2018 Sterilization of health care products – Microbiological methods – Part 1: Determination of a population of microorganisms on products
0 out of 5CDN $312.00 Add to cart