Your cart is currently empty!

ISO 21439:2009
ISO 21439:2009 Clinical dosimetry – Beta radiation sources for brachytherapy
CDN $390.00
Description
ISO 21439:2009 specifies methods for the determination of absorbed-dose distributions in water or tissue that are required prior to initiating procedures for the application of beta radiation in ophthalmic tumour and intravascular brachytherapy]. Recommendations are given for beta-radiation source calibration, dosemetry measurements, dose calculation, dosemetric quality assurance, as well as for beta-radiation brachytherapy treatment planning. Guidance is also given for estimating the uncertainty of the absorbed dose to water. ISO 21439:2009 is applicable to “sealed” radioactive sources, such as plane and concave surface sources, source trains of single seeds, line sources, shell and volume sources, for which only the beta radiation emitted is of therapeutic relevance.
The standardization of procedures in clinical dosemetry described in ISO 21439:2009 serves as a basis for the reliable application of beta-radiation brachytherapy. The specific dosemetric methods described in ISO 21439:2009 apply to sources for the curative treatment of ophthalmic disease, for intravascular brachytherapy treatment, for overcoming the problem of restenosis and for other clinical applications using beta radiation.
ISO 21439:2009 is geared towards organizations wishing to establish reference methods in dosemetry aiming at clinical demands for an appropriately small uncertainty of the delivered dose. ISO 21439:2009 does not exclude the possibility that there can be other methods leading to the same or smaller measurement uncertainties.
Edition
1
Published Date
2009-01-29
Status
PUBLISHED
Pages
92
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment

Abstract
ISO 21439:2009 specifies methods for the determination of absorbed-dose distributions in water or tissue that are required prior to initiating procedures for the application of beta radiation in ophthalmic tumour and intravascular brachytherapy]. Recommendations are given for beta-radiation source calibration, dosemetry measurements, dose calculation, dosemetric quality assurance, as well as for beta-radiation brachytherapy treatment planning. Guidance is also given for estimating the uncertainty of the absorbed dose to water. ISO 21439:2009 is applicable to “sealed” radioactive sources, such as plane and concave surface sources, source trains of single seeds, line sources, shell and volume sources, for which only the beta radiation emitted is of therapeutic relevance.
The standardization of procedures in clinical dosemetry described in ISO 21439:2009 serves as a basis for the reliable application of beta-radiation brachytherapy. The specific dosemetric methods described in ISO 21439:2009 apply to sources for the curative treatment of ophthalmic disease, for intravascular brachytherapy treatment, for overcoming the problem of restenosis and for other clinical applications using beta radiation.
ISO 21439:2009 is geared towards organizations wishing to establish reference methods in dosemetry aiming at clinical demands for an appropriately small uncertainty of the delivered dose. ISO 21439:2009 does not exclude the possibility that there can be other methods leading to the same or smaller measurement uncertainties.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-
ISO 13164:2023 Water quality – Radon-222 – Part 4: Test method using two-phase liquid scintillation counting
0 out of 5CDN $173.00 Add to cart -
ISO 13161:2020 Water quality – Polonium 210 – Test method using alpha spectrometry
0 out of 5CDN $233.00 Add to cart -
ISO 13167:2023 Water quality – Plutonium, americium, curium and neptunium – Test method using alpha spectrometry
0 out of 5CDN $273.00 Add to cart -
ISO 11665:2019 Measurement of radioactivity in the environment – Air: radon-222 – Part 8: Methodologies for initial and additional investigations in buildings
0 out of 5CDN $233.00 Add to cart