REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

API RP 1173: Pipeline Safety Management Systems

$

167

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 1173: Pipeline Safety Management Systems : Errata 1

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 11S2: Electric Submersible Pump Testing: Edition 3

$

158

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 14L: Lock Mandrels and Landing Nipples : Reaffirmed

$

273

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 20F: Corrosion Resistant Bolting for Use in the Petroleum and Natural Gas Industries : Reaffirmed

$

169

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 5NCL Nickel Content Limits for API 5CT Sour Service Products

$

149

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 19ICD: Inflow Control Devices : Reaffirmed

$

189

BUY NOW

ISO 22156:2021

ISO 22156:2021 Bamboo structures – Bamboo culms – Structural design

CDN $312.00

SKU: 2c8b27075fe9 Categories: ,

Description

This document applies to the design of bamboo structures whose primary load bearing structure is made of round bamboo or shear panel systems in which the framing members are made from round bamboo.

Except as indicated in Clause 12, this document applies to one- and two-storey residential, small commercial or institutional and light industrial buildings not exceeding 7 m in height.

This document is concerned only with requirements for mechanical resistance, serviceability and durability of bamboo structures.

This document permits an allowable load-bearing capacity design (ACD) and/or allowable stress design (ASD) approach for the design of bamboo structures. Allowable load-bearing capacity and allowable stress approaches may be used in combination in the same structure.

This document additionally recognises design approaches based on partial safety factor design (PSFD) and/or load and resistance factor design (LRFD) methods (5.11.1), previous established experience (5.11.2), or documented ‘design by testing’ approaches (5.11.3).

Other requirements, such as those concerning thermal or sound insulation, are not considered. Bamboo structures may require consideration of additional requirements beyond the scope of this document. Execution is covered to the extent that it impacts the quality of construction materials and products required to comply with the design requirements contained herein.

This document provides a number of modification factors, designated Ci. These are empirically derived factors, based on best available engineering judgement, that are believed to be universally applicable to bamboo materials that are appropriate for building construction. Parameters affecting bamboo material performance are many and are addressed explicitly through the use of experimentally determined characteristic values of strength and stiffness. Annex A provides a summary of the bases upon which the provisions of this document were developed.

This document does not apply to

-    structures made of engineered bamboo products such as glue-laminated bamboo, cross-laminated bamboo, oriented strand, or densified bamboo materials,

-    bamboo-reinforced materials where bamboo is not the primary load-bearing constituent. This includes bamboo-reinforced concrete, masonry and soil, or,

-    scaffold structures constructed with bamboo.

Edition

2

Published Date

2021-06-03

Status

PUBLISHED

Pages

48

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document applies to the design of bamboo structures whose primary load bearing structure is made of round bamboo or shear panel systems in which the framing members are made from round bamboo.

Except as indicated in Clause 12, this document applies to one- and two-storey residential, small commercial or institutional and light industrial buildings not exceeding 7 m in height.

This document is concerned only with requirements for mechanical resistance, serviceability and durability of bamboo structures.

This document permits an allowable load-bearing capacity design (ACD) and/or allowable stress design (ASD) approach for the design of bamboo structures. Allowable load-bearing capacity and allowable stress approaches may be used in combination in the same structure.

This document additionally recognises design approaches based on partial safety factor design (PSFD) and/or load and resistance factor design (LRFD) methods (5.11.1), previous established experience (5.11.2), or documented ‘design by testing’ approaches (5.11.3).

Other requirements, such as those concerning thermal or sound insulation, are not considered. Bamboo structures may require consideration of additional requirements beyond the scope of this document. Execution is covered to the extent that it impacts the quality of construction materials and products required to comply with the design requirements contained herein.

This document provides a number of modification factors, designated Ci. These are empirically derived factors, based on best available engineering judgement, that are believed to be universally applicable to bamboo materials that are appropriate for building construction. Parameters affecting bamboo material performance are many and are addressed explicitly through the use of experimentally determined characteristic values of strength and stiffness. Annex A provides a summary of the bases upon which the provisions of this document were developed.

This document does not apply to

-    structures made of engineered bamboo products such as glue-laminated bamboo, cross-laminated bamboo, oriented strand, or densified bamboo materials,

-    bamboo-reinforced materials where bamboo is not the primary load-bearing constituent. This includes bamboo-reinforced concrete, masonry and soil, or,

-    scaffold structures constructed with bamboo.

Previous Editions

Can’t find what you are looking for?

Please contact us at: