Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

B51-14 (R2019) – Boiler, pressure vessel, and pressure piping code

$

362

BUY NOW

ISO 23443:2020

ISO 23443:2020 Infant formula and adult nutritionals – Determination of Œ≤-carotene, lycopene and lutein by reversed-phase ultra-high performance liquid chromatography (RP-UHPLC)

CDN $305.00

SKU: 50d85edf2576 Category:

Description

This document specifies a method for the quantitative determination of β-carotene and lycopene in infant formula and adult nutritionals in solid (i.e. powders) or liquid (i.e. ready-to-feed liquids and liquid concentrates) forms using reversed-phase ultra-high performance liquid chromatography (RP-UHPLC) and UV-visible detection. The application range runs from 1 μg/100 g to 1 500 μg/100 g for lycopene and from 1 μg/100 g to 2 250 μg/100 g for β-carotene. Based on the single-laboratory validation, the limit of detection (LOD) was 0,1 μg/100 g and the limit of quantification (LOQ) was 0,3 μg/100 g for each carotenoid.

The method does not apply to materials that contain measurable levels of β-apo-8′-carotenal. The reproducibility data meets the requirements given in References [8] and [10].

Annex C specifies the determination of lutein. The reproducibility data does not meet the requirements given in Reference [9].

Edition

1

Published Date

2020-07-02

Status

PUBLISHED

Pages

32

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies a method for the quantitative determination of β-carotene and lycopene in infant formula and adult nutritionals in solid (i.e. powders) or liquid (i.e. ready-to-feed liquids and liquid concentrates) forms using reversed-phase ultra-high performance liquid chromatography (RP-UHPLC) and UV-visible detection. The application range runs from 1 μg/100 g to 1 500 μg/100 g for lycopene and from 1 μg/100 g to 2 250 μg/100 g for β-carotene. Based on the single-laboratory validation, the limit of detection (LOD) was 0,1 μg/100 g and the limit of quantification (LOQ) was 0,3 μg/100 g for each carotenoid.

The method does not apply to materials that contain measurable levels of β-apo-8′-carotenal. The reproducibility data meets the requirements given in References [8] and [10].

Annex C specifies the determination of lutein. The reproducibility data does not meet the requirements given in Reference [9].

Previous Editions

Can’t find what you are looking for?

Please contact us at: