REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

API MPMS CH 22.6: Testing Protocols for Gas Chromatographs : Reaffirmed

$

192

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 1174: Onshore Hazardous Liquid Pipeline Emergency Preparedness and Response : Reaffirmed

$

182

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 624: Type Testing of Rising Stem Valves Equipped with Flexible Graphite Packing for Fugitive

$

171

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 20G: Welding Services for Equipment used in the Petroleum and Natural Gas Industry : Reaffirmed

$

164

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 624: Errata 2

$

0.00

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 1173: Pipeline Safety Management Systems

$

167

BUY NOW

ISO 23551:2024

ISO 23551:2024 Safety and control devices for gas burners and gas-burning appliances – Particular requirements – Part 1: Automatic and semi-automatic shut-off valves

CDN $273.00

Description

This document specifies safety, constructional and performance requirements and testing of automatic, semi-automatic shut-off valves and general purpose valves for gas burners, gas appliances and appliances of similar use, hereinafter referred to as valves.

This document applies to normally closed valves and general purpose valves mounted upstream to gas burners and gas appliances with declared maximum operating pressures up to and including 500 kPa, for use on burners or in appliances using fuel gases such as natural gas, manufactured gas or liquefied petroleum gas (LPG). It is not applicable to corrosive and waste gases.

This document applies to:

     valves directly or indirectly actuated, electrically or by mechanical means;

     valves actuated by hydraulic or pneumatic means;

     valves where the flow rate is controlled by external electrical signals, either in discrete steps or proportional to the applied signal; and

     valves fitted with closed position indicator switches.

This document covers type testing only.

Edition

3

Published Date

2024-11-22

Status

PUBLISHED

Pages

35

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies safety, constructional and performance requirements and testing of automatic, semi-automatic shut-off valves and general purpose valves for gas burners, gas appliances and appliances of similar use, hereinafter referred to as valves.

This document applies to normally closed valves and general purpose valves mounted upstream to gas burners and gas appliances with declared maximum operating pressures up to and including 500 kPa, for use on burners or in appliances using fuel gases such as natural gas, manufactured gas or liquefied petroleum gas (LPG). It is not applicable to corrosive and waste gases.

This document applies to:

-     valves directly or indirectly actuated, electrically or by mechanical means;

-     valves actuated by hydraulic or pneumatic means;

-     valves where the flow rate is controlled by external electrical signals, either in discrete steps or proportional to the applied signal; and

-     valves fitted with closed position indicator switches.

This document covers type testing only.

Previous Editions

Can’t find what you are looking for?

Please contact us at: