Search
×
FR

Placeholder headline

This is just a placeholder headline

API STD 521: Guide for Pressure-relieving and Depressuring Systems – Edition 6

$

682

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 653: Tank Inspection, Repair, Alteration, and Reconstruction – Edition 4

$

507

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:19 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series-18: Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z246.2-14 – Emergency preparedness and response for petroleum and natural gas industry systems

$

596

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:22 – Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z731-09 (R2014) – Emergency Preparedness and Response

$

177

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:23 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:26 – Storage of Hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA B51:24 Boiler, Pressure Vessel, and Pressure Piping Code

$

389

BUY NOW

ISO 23830:2008

ISO 23830:2008 Surface chemical analysis – Secondary-ion mass spectrometry – Repeatability and constancy of the relative-intensity scale in static secondary-ion mass spectrometry

CDN $124.00

SKU: 31fe03236bd8 Categories: ,

Description

ISO 23830:2008 specifies a method for confirming the repeatability and constancy of the positive-ion relative-intensity scale of static secondary-ion mass spectrometers, for general analytical purposes. It is only applicable to instruments that incorporate an electron gun for charge neutralization. It is not intended to be a calibration of the intensity/mass response function. That calibration may be made by the instrument manufacturer or another organization. The present method provides data to confirm the constancy of relative intensities with instrument usage. Guidance is given on some of the instrument settings that may affect this constancy.

Edition

1

Published Date

2008-11-05

Status

PUBLISHED

Pages

12

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 23830:2008 specifies a method for confirming the repeatability and constancy of the positive-ion relative-intensity scale of static secondary-ion mass spectrometers, for general analytical purposes. It is only applicable to instruments that incorporate an electron gun for charge neutralization. It is not intended to be a calibration of the intensity/mass response function. That calibration may be made by the instrument manufacturer or another organization. The present method provides data to confirm the constancy of relative intensities with instrument usage. Guidance is given on some of the instrument settings that may affect this constancy.

Previous Editions

Can’t find what you are looking for?

Please contact us at: