The design method provided in this document addresses vibration induced by walking action of occupants and covers the following timber floor systems:
a)       Light frame floors built with timber joists spaced at a distance of no more than 610 mm with a layer of structural wood-based subfloor that is connected to the joists using mechanical fasteners or adhesive. The area density of a bare light frame floors without a screed (topping) and ceiling is not greater than 25 kg/m2. Figure 1 shows such a light frame floor.
b)       Mass timber floors built with mass timber panels such as cross laminated timber (CLT).
This document consists of three elements:
a)       a baseline vibrational serviceability design criterion for timber floors using fundamental natural frequency and 1 kN static point load deflection as the design parameters including two types of design criteria, coupled and decoupled criteria;
b)       equations for calculating the design parameters;
c)        guidelines for the design values of the physical and mechanical properties of floor components.
The design method is based on the assumption that the floor system has a single span and simple support conditions.
Edition
1
Published Date
2023-12-08
Status
PUBLISHED
Pages
15
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment

Abstract
The design method provided in this document addresses vibration induced by walking action of occupants and covers the following timber floor systems:
a)       Light frame floors built with timber joists spaced at a distance of no more than 610 mm with a layer of structural wood-based subfloor that is connected to the joists using mechanical fasteners or adhesive. The area density of a bare light frame floors without a screed (topping) and ceiling is not greater than 25 kg/m2. Figure 1 shows such a light frame floor.
b)       Mass timber floors built with mass timber panels such as cross laminated timber (CLT).
This document consists of three elements:
a)       a baseline vibrational serviceability design criterion for timber floors using fundamental natural frequency and 1 kN static point load deflection as the design parameters including two types of design criteria, coupled and decoupled criteria;
b)       equations for calculating the design parameters;
c)        guidelines for the design values of the physical and mechanical properties of floor components.
The design method is based on the assumption that the floor system has a single span and simple support conditions.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-
ISO 8927:1991 Earth-moving machinery – Machine availability – Vocabulary
0 out of 5CDN $233.00 Add to cart -
ISO 10110:2019 Optics and photonics – Preparation of drawings for optical elements and systems – Part 1: General
0 out of 5CDN $312.00 Add to cart -
ISO 14416:2003 Information and documentation – Requirements for binding of books, periodicals, serials and other paper documents for archive and library use – Methods and materials
0 out of 5CDN $273.00 Add to cart -
ISO 2574:1994 Aircraft – Electrical cables – Identification marking
0 out of 5CDN $115.00 Add to cart