REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

API RP 1173: Pipeline Safety Management Systems

$

167

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 1173: Pipeline Safety Management Systems : Errata 1

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 11S2: Electric Submersible Pump Testing: Edition 3

$

158

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 14L: Lock Mandrels and Landing Nipples : Reaffirmed

$

273

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 20F: Corrosion Resistant Bolting for Use in the Petroleum and Natural Gas Industries : Reaffirmed

$

169

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 5NCL Nickel Content Limits for API 5CT Sour Service Products

$

149

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 19ICD: Inflow Control Devices : Reaffirmed

$

189

BUY NOW

ISO 24323:2023

ISO 24323:2023 Timber structures – Design method for vibrational serviceability of timber floors

CDN $173.00

Description

The design method provided in this document addresses vibration induced by walking action of occupants and covers the following timber floor systems:

a)       Light frame floors built with timber joists spaced at a distance of no more than 610 mm with a layer of structural wood-based subfloor that is connected to the joists using mechanical fasteners or adhesive. The area density of a bare light frame floors without a screed (topping) and ceiling is not greater than 25 kg/m2. Figure 1 shows such a light frame floor.

b)       Mass timber floors built with mass timber panels such as cross laminated timber (CLT).

This document consists of three elements:

a)       a baseline vibrational serviceability design criterion for timber floors using fundamental natural frequency and 1 kN static point load deflection as the design parameters including two types of design criteria, coupled and decoupled criteria;

b)       equations for calculating the design parameters;

c)        guidelines for the design values of the physical and mechanical properties of floor components.

The design method is based on the assumption that the floor system has a single span and simple support conditions.

Edition

1

Published Date

2023-12-08

Status

PUBLISHED

Pages

15

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

The design method provided in this document addresses vibration induced by walking action of occupants and covers the following timber floor systems:

a)       Light frame floors built with timber joists spaced at a distance of no more than 610 mm with a layer of structural wood-based subfloor that is connected to the joists using mechanical fasteners or adhesive. The area density of a bare light frame floors without a screed (topping) and ceiling is not greater than 25 kg/m2. Figure 1 shows such a light frame floor.

b)       Mass timber floors built with mass timber panels such as cross laminated timber (CLT).

This document consists of three elements:

a)       a baseline vibrational serviceability design criterion for timber floors using fundamental natural frequency and 1 kN static point load deflection as the design parameters including two types of design criteria, coupled and decoupled criteria;

b)       equations for calculating the design parameters;

c)        guidelines for the design values of the physical and mechanical properties of floor components.

The design method is based on the assumption that the floor system has a single span and simple support conditions.

Previous Editions

Can’t find what you are looking for?

Please contact us at: