ISO 25424:2018
ISO 25424:2018 Sterilization of health care products – Low temperature steam and formaldehyde – Requirements for development, validation and routine control of a sterilization process for medical devices
CDN $312.00
Description
1.1 Inclusions
1.1.1 This document specifies requirements for the development, validation and routine control of a low temperature steam and formaldehyde (LTSF) sterilization process for medical devices using a mixture of low temperature steam and formaldehyde as sterilizing agent and which operates below ambient pressure.
NOTE Although the scope of this document is limited to medical devices, it specifies requirements and provides guidance that can be applicable to other products and equipment.
1.1.2 This document is intended to be applied by process developers, manufacturers of sterilization equipment, manufacturers of medical devices to be sterilized and the organizations with responsibility for sterilizing medical devices (see ISO 14937:2009, Table E.1).
1.2 Exclusions
1.2.1 This document does not specify requirements for the development, validation and routine control of a process for inactivating the causative agents of spongiform encephalopathies such as scrapie, bovine spongiform encephalopathy and Creutzfeldt-Jakob disease. Specific recommendations have been produced in particular countries for the processing of materials potentially contaminated with these agents.
NOTE See ISO 22442‚Äë1, ISO 22442‚Äë2 and ISO 22442‚Äë3.
1.2.2 This document does not specify requirements for designating a medical device as “STERILE”. Such requirements are given in EN 556‚Äë1.
1.2.3 This document does not specify a quality management system for the control of all stages of production of medical devices.
NOTE It is not a requirement of this document to have a complete quality management system during manufacture or reprocessing, but those elements of such a system that are required are normatively referenced at appropriate places in the text. Attention is drawn to the standards for quality management systems (see ISO 13485) that control all stages of production or reprocessing of medical devices including the sterilization process. Further guidance is given in E.4 of ISO 14937:2009.
1.2.4 This document does not specify requirements for occupational safety associated with the design and operation of LTSF sterilization facilities.
NOTE 1 Safety requirements for sterilizers are specified in IEC 61010‚Äë2‚Äë040.
NOTE 2 Attention is also drawn to the existence in some countries of regulations stipulating safety requirements.
1.2.5 This document does not cover analytical methods for determining levels or residues of formaldehyde and/or its reaction products.
NOTE 1 Attention is drawn to EN 14180.
NOTE 2 Attention is drawn to the possible existence in some countries of statutory regulations specifying limits for the level of formaldehyde residues on medical devices and products.
1.2.6 This document does not cover preparatory measures that might be necessary before sterilization such as cleaning, disinfection and packing.
NOTE For reprocessable medical devices, the manufacturer(s) of these devices can supply information on the preparatory measures (see ISO 17664).
Edition
2
Published Date
2018-10-19
Status
PUBLISHED
Pages
41
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment

Abstract
1.1 Inclusions
1.1.1 This document specifies requirements for the development, validation and routine control of a low temperature steam and formaldehyde (LTSF) sterilization process for medical devices using a mixture of low temperature steam and formaldehyde as sterilizing agent and which operates below ambient pressure.
NOTE Although the scope of this document is limited to medical devices, it specifies requirements and provides guidance that can be applicable to other products and equipment.
1.1.2 This document is intended to be applied by process developers, manufacturers of sterilization equipment, manufacturers of medical devices to be sterilized and the organizations with responsibility for sterilizing medical devices (see ISO 14937:2009, Table E.1).
1.2 Exclusions
1.2.1 This document does not specify requirements for the development, validation and routine control of a process for inactivating the causative agents of spongiform encephalopathies such as scrapie, bovine spongiform encephalopathy and Creutzfeldt-Jakob disease. Specific recommendations have been produced in particular countries for the processing of materials potentially contaminated with these agents.
NOTE See ISO 22442‚Äë1, ISO 22442‚Äë2 and ISO 22442‚Äë3.
1.2.2 This document does not specify requirements for designating a medical device as "STERILE". Such requirements are given in EN 556‚Äë1.
1.2.3 This document does not specify a quality management system for the control of all stages of production of medical devices.
NOTE It is not a requirement of this document to have a complete quality management system during manufacture or reprocessing, but those elements of such a system that are required are normatively referenced at appropriate places in the text. Attention is drawn to the standards for quality management systems (see ISO 13485) that control all stages of production or reprocessing of medical devices including the sterilization process. Further guidance is given in E.4 of ISO 14937:2009.
1.2.4 This document does not specify requirements for occupational safety associated with the design and operation of LTSF sterilization facilities.
NOTE 1 Safety requirements for sterilizers are specified in IEC 61010‚Äë2‚Äë040.
NOTE 2 Attention is also drawn to the existence in some countries of regulations stipulating safety requirements.
1.2.5 This document does not cover analytical methods for determining levels or residues of formaldehyde and/or its reaction products.
NOTE 1 Attention is drawn to EN 14180.
NOTE 2 Attention is drawn to the possible existence in some countries of statutory regulations specifying limits for the level of formaldehyde residues on medical devices and products.
1.2.6 This document does not cover preparatory measures that might be necessary before sterilization such as cleaning, disinfection and packing.
NOTE For reprocessable medical devices, the manufacturer(s) of these devices can supply information on the preparatory measures (see ISO 17664).
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-
ISO 20712:2024 Water safety signs and beach safety flags – Part 3: Guidance for use
0 out of 5CDN $233.00 Add to cart -
ISO 4125:1991 Dry fruits and dried fruits – Definitions and nomenclature
0 out of 5CDN $76.00 Add to cart -
ISO 20537:2025 Footwear – Identification of defects during visual inspection – Vocabulary
0 out of 5CDN $273.00 Add to cart -
ISO 15416:2025 Automatic identification and data capture techniques – Bar code print quality test specification – Linear symbols
0 out of 5CDN $312.00 Add to cart