REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

MSS SP-165-2025 – Large Diameter Slip-On and Lap Joint Flanges

$

393

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 4.1: Proving Systems – Introduction : Reaffirmed

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 11B: Sucker Rods and Rod-related Products

$

309

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 11B: Sucker Rods and Rod-related Products : Addendum 1

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 19GLHB: Gas Lift Handbook

$

316

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 14.4: Converting Mass of Natural Gas Liquids or Vapors to Equivalent Liquid Volumes

$

144

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 19GLHB: Addenda 3

$

0

BUY NOW

ISO 3251:2019

ISO 3251:2019 Paints, varnishes and plastics – Determination of non-volatile-matter content

CDN $115.00

Description

This document specifies a method for determining the non-volatile-matter content by mass of paints, varnishes, binders for paints and varnishes, polymer dispersions and condensation resins such as phenolic resins (resols, novolak solutions etc.).

The method is also applicable to formulated dispersions containing fillers, pigments and other auxiliaries (e.g. thickeners, film-forming agents).

NOTE 1 The non-volatile-matter content of a product is not an absolute quantity but depends upon the temperature and period of heating used for the determination. Consequently, when using this method, only relative and not true values for non-volatile-matter content are obtained owing to solvent retention, thermal decomposition and evaporation of low molecular mass constituents. The method is therefore primarily intended for testing different batches of the same type of product.

NOTE 2 This method is suitable for synthetic rubber lattices, provided heating for a specific period of time is considered appropriate (ISO 124 specifies heating until the loss in mass of a 2 g test portion following successive periods of heating is less than 0,5 mg).

NOTE 3 In-house methods for determining non-volatile matter often include drying with infrared or microwave radiation. Standardization of such methods is not possible, since they are not generally applicable. Several polymer compositions tend to decompose during such treatment and therefore give incorrect results.

Edition

5

Published Date

2019-05-14

Status

PUBLISHED

Pages

8

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies a method for determining the non-volatile-matter content by mass of paints, varnishes, binders for paints and varnishes, polymer dispersions and condensation resins such as phenolic resins (resols, novolak solutions etc.).

The method is also applicable to formulated dispersions containing fillers, pigments and other auxiliaries (e.g. thickeners, film-forming agents).

NOTE 1 The non-volatile-matter content of a product is not an absolute quantity but depends upon the temperature and period of heating used for the determination. Consequently, when using this method, only relative and not true values for non-volatile-matter content are obtained owing to solvent retention, thermal decomposition and evaporation of low molecular mass constituents. The method is therefore primarily intended for testing different batches of the same type of product.

NOTE 2 This method is suitable for synthetic rubber lattices, provided heating for a specific period of time is considered appropriate (ISO 124 specifies heating until the loss in mass of a 2 g test portion following successive periods of heating is less than 0,5 mg).

NOTE 3 In-house methods for determining non-volatile matter often include drying with infrared or microwave radiation. Standardization of such methods is not possible, since they are not generally applicable. Several polymer compositions tend to decompose during such treatment and therefore give incorrect results.