ISO 6145:2017
ISO 6145:2017 Gas analysis – Preparation of calibration gas mixtures using dynamic methods – Part 6: Critical flow orifices
CDN $295.00
Description
ISO 6145-6:2017 specifies a method for the dynamic preparation of calibration gas mixtures containing at least two gases (usually one of them is a complementary gas) from pure gases or gas pre-mixtures using critical flow orifices systems.
The method applies principally to the preparation of mixtures of non-reactive gases that do not react with any of the materials forming the gas circuit inside the critical flow orifices system or auxiliary equipment. It has the merit of allowing multi-component mixtures to be prepared as readily as binary mixtures if an appropriate number of critical flow orifices are used.
By selecting appropriate combinations of critical flow orifices, a dilution ratio of 1 √ó 104 is achievable.
Although it is more particularly applicable to the preparation of gas mixtures at atmospheric pressure, the method also offers the possibility of preparing calibration gas mixtures at pressures greater than atmospheric. The upstream pressure will need to be at least two times higher than downstream pressure.
The range of flow rates covered by this document extends from 1 ml/min to 10 l/min.
Edition
3
Published Date
2017-07-11
Status
PUBLISHED
Pages
27
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO 6145-6:2017 specifies a method for the dynamic preparation of calibration gas mixtures containing at least two gases (usually one of them is a complementary gas) from pure gases or gas pre-mixtures using critical flow orifices systems.
The method applies principally to the preparation of mixtures of non-reactive gases that do not react with any of the materials forming the gas circuit inside the critical flow orifices system or auxiliary equipment. It has the merit of allowing multi-component mixtures to be prepared as readily as binary mixtures if an appropriate number of critical flow orifices are used.
By selecting appropriate combinations of critical flow orifices, a dilution ratio of 1 √ó 104 is achievable.
Although it is more particularly applicable to the preparation of gas mixtures at atmospheric pressure, the method also offers the possibility of preparing calibration gas mixtures at pressures greater than atmospheric. The upstream pressure will need to be at least two times higher than downstream pressure.
The range of flow rates covered by this document extends from 1 ml/min to 10 l/min.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 5078:2025 Management of terminology resources – Terminology extraction
CDN $251.00 Add to cart -

ISO 14416:2003 Information and documentation – Requirements for binding of books, periodicals, serials and other paper documents for archive and library use – Methods and materials
CDN $295.00 Add to cart -

ISO 2382:2015 Information technology – Vocabulary
CDN $0.00 Add to cart -

ISO 16840:2006 Wheelchair seating – Part 1: Vocabulary, reference axis convention and measures for body segments, posture and postural support surfaces
CDN $379.00 Add to cart