Search
×
FR

Placeholder headline

This is just a placeholder headline

API STD 521: Guide for Pressure-relieving and Depressuring Systems – Edition 6

$

682

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 653: Tank Inspection, Repair, Alteration, and Reconstruction – Edition 4

$

507

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:19 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series-18: Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z246.2-14 – Emergency preparedness and response for petroleum and natural gas industry systems

$

596

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:22 – Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z731-09 (R2014) – Emergency Preparedness and Response

$

177

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:23 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:26 – Storage of Hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA B51:24 Boiler, Pressure Vessel, and Pressure Piping Code

$

389

BUY NOW

ISO 6145:2002

ISO 6145:2002 Gas analysis – Preparation of calibration gas mixtures using dynamic volumetric methods – Part 10: Permeation method

CDN $186.00

SKU: 62706f7d699a Categories: ,

Description

This part of ISO 6145 specifies a dynamic method using permeation membranes for the preparation of calibration

gas mixtures containing component mole fractions ranging from 10‚àí9 and 10‚àí6. A relative expanded uncertainty of

2,5 % of the component mole fraction can be achieved using this method. In the mole fraction range considered, it

is difficult to maintain some gas mixtures, for example in cylinders, in a stable state. It is therefore desirable to

prepare the calibration gas immediately before use, and to transfer it by the shortest possible path to the place

where it is to be used. This technique has been successfully applied in generating low content calibration gas

mixtures of, for example, sulfur dioxide (SO2), nitrogen dioxide (NO2) and benzene (C6H6) in air.

If the carrier gas flow is measured as a gas mass-flow, the preparation of calibration gas mixtures using permeation

tubes is a dynamic-gravimetric method which gives contents in mole fractions.

Edition

1

Published Date

2002-02-07

Status

PUBLISHED

Pages

16

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This part of ISO 6145 specifies a dynamic method using permeation membranes for the preparation of calibration

gas mixtures containing component mole fractions ranging from 10‚àí9 and 10‚àí6. A relative expanded uncertainty of

2,5 % of the component mole fraction can be achieved using this method. In the mole fraction range considered, it

is difficult to maintain some gas mixtures, for example in cylinders, in a stable state. It is therefore desirable to

prepare the calibration gas immediately before use, and to transfer it by the shortest possible path to the place

where it is to be used. This technique has been successfully applied in generating low content calibration gas

mixtures of, for example, sulfur dioxide (SO2), nitrogen dioxide (NO2) and benzene (C6H6) in air.

If the carrier gas flow is measured as a gas mass-flow, the preparation of calibration gas mixtures using permeation

tubes is a dynamic-gravimetric method which gives contents in mole fractions.