Search
×
FR

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-6 Chapter 6 – Density

$

204

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 560: Fired Heaters for General Refinery Services

$

721

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 64: Diverter Equipment Systems

$

324

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 17.10.1: Refrigerated Light Hydrocarbon Fluids – Measurement of Cargoes on Board LNG Carries

$

417

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-1: Testing Water-based Drilling Fluids

$

418

BUY NOW

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-12 Chapter 12 – Thermal Conductivity

$

214

BUY NOW

Placeholder headline

This is just a placeholder headline

API 16FI Frac Iron Guidelines and Requirements

$

129

BUY NOW

ISO 760:1978

ISO 760:1978 Determination of water – Karl Fischer method (General method)

CDN $115.00

SKU: 91509cf40825 Category:

Description

Two methods of titration depending on whether the end point is detected visually or electrometrically are specified. The visual method is only applicable to colourless solutions but can be used when no electrometric apparatus is available. The electrometric method, whether by direct titration or back-titration, is the more accurate one and for this reason recommended. The principle of the test consists in reaction of any water present in a test portion with a solution of iodine and sulphur dioxide in a pyridine/methanol mixture (Karl Fischer reagent), previously standardized by titration with an exactly known mass of water.

Edition

1

Published Date

1978-12-01

Status

PUBLISHED

Pages

12

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Two methods of titration depending on whether the end point is detected visually or electrometrically are specified. The visual method is only applicable to colourless solutions but can be used when no electrometric apparatus is available. The electrometric method, whether by direct titration or back-titration, is the more accurate one and for this reason recommended. The principle of the test consists in reaction of any water present in a test portion with a solution of iodine and sulphur dioxide in a pyridine/methanol mixture (Karl Fischer reagent), previously standardized by titration with an exactly known mass of water.