REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

API MPMS CH 22.6: Testing Protocols for Gas Chromatographs : Reaffirmed

$

192

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 1174: Onshore Hazardous Liquid Pipeline Emergency Preparedness and Response : Reaffirmed

$

182

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 624: Type Testing of Rising Stem Valves Equipped with Flexible Graphite Packing for Fugitive

$

171

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 20G: Welding Services for Equipment used in the Petroleum and Natural Gas Industry : Reaffirmed

$

164

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 624: Errata 2

$

0.00

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 1173: Pipeline Safety Management Systems

$

167

BUY NOW

ISO 80601:2019

ISO 80601:2019 Medical electrical equipment – Part 2-26: Particular requirements for the basic safety and essential performance of electroencephalographs

CDN $441.00

SKU: ae5e06f690ce Category:

Description

This part of the 80601 International Standard applies to the basic safety and essential performance of electroencephalographs as defined in 201.3.204, hereafter also referred to as me equipment or me system. This document is applicable to electroencephalographs intended for use in professional healthcare facilities, the emergency medical services environment or the home healthcare environment.

This document does not cover requirements for other equipment used in electroencephalography such as:

– phono-photic stimulators;

– EEG data storage and retrieval;

– ME EQUIPMENT particularly intended for monitoring during electroconvulsive therapy.

If a clause or subclause is specifically intended to be applicable to me equipment only, or to me systems only, the title or content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to me equipment and to me systems, as follows.

The clause or subclause applies to me equipment, as default. For me equipment with the corresponding safety measure or function not completely integrated into the me equipment but instead implemented in an me system, the me equipment manufacturer specifies in the accompanying documents which functionality and safety requirements are provided by the me system to comply with this document. The me system is verified accordingly.

Hazards inherent in the intended physiological function of me equipment or me systems within the scope of this document are not covered by specific requirements in this document.

NOTE‚ÄÉSee also 4.2 of the general standard.

Edition

1

Published Date

2019-05-22

Status

PUBLISHED

Pages

75

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This part of the 80601 International Standard applies to the basic safety and essential performance of electroencephalographs as defined in 201.3.204, hereafter also referred to as me equipment or me system. This document is applicable to electroencephalographs intended for use in professional healthcare facilities, the emergency medical services environment or the home healthcare environment.

This document does not cover requirements for other equipment used in electroencephalography such as:

- phono-photic stimulators;

- EEG data storage and retrieval;

- ME EQUIPMENT particularly intended for monitoring during electroconvulsive therapy.

If a clause or subclause is specifically intended to be applicable to me equipment only, or to me systems only, the title or content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to me equipment and to me systems, as follows.

The clause or subclause applies to me equipment, as default. For me equipment with the corresponding safety measure or function not completely integrated into the me equipment but instead implemented in an me system, the me equipment manufacturer specifies in the accompanying documents which functionality and safety requirements are provided by the me system to comply with this document. The me system is verified accordingly.

Hazards inherent in the intended physiological function of me equipment or me systems within the scope of this document are not covered by specific requirements in this document.

NOTE‚ÄÉSee also 4.2 of the general standard.