REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

API STD 670: Machinery Protection Systems

$

423

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 17.5: Guidelines for Cargo Analysis and Reconciliation

$

252

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 603: Corrosion-Resistant, Bolted Bonnet Gate Valves–Flanged and Butt-Welding Ends

$

205

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 653: Tank Inspection, Repair, Alteration, and Reconstruction

$

460

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 12R1: Installation, Operation, Maintenance, Inspection, and Repair of Tanks in Production Service

$

285

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 653: Tank Inspection, Repair, Alteration, and Reconstruction: Addendum 4

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 9A: Specification for Wire Rope

$

248

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 575: Inspection Practices for Atmospheric and Low-Pressure Storage Tanks

$

416

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 9A: Addenda 2

$

0

BUY NOW

ISO 9847:2023

ISO 9847:2023 Solar energy – Calibration of pyranometers by comparison to a reference pyranometer

CDN $273.00

Description

This document specifies two preferred methods for the calibration of pyranometers using reference pyranometers; indoor (Type A) and outdoor (Type B).

Indoor or type A calibration, is performed against a lamp source, while the outdoor method B, employs natural solar radiation as the source.

Indoor calibration is performed either at normal incidence (type A1), the receiver surface perpendicular to the beam of the lamp or under exposure to a uniform diffuse lamp source using an integrating sphere (type A2).

Outdoor calibration is performed using the sun as a source, with the pyranometer in a horizontal position (type B1), in a tilted position (type B2), or at normal incidence (type B3).

Calibrations according to the specified methods will be traceable to SI, through the world radiometric reference (WRR), provided that traceable reference instruments are used.

This document is applicable to most types of pyranometers regardless of the type technology employed. The methods have been validated for pyranometers that comply with the requirements for classes A, B and C of ISO 9060. In general, all pyranometers may be calibrated by using the described methods, provided that a proper uncertainty evaluation is performed.

Unlike spectrally flat pyranometers, non-spectrally flat pyranometers might have a spectral response that varies strongly with the wavelength even within the spectral range from 300 to 1 500 nm, and therefore the calibration result may possibly be valid under a more limited range of conditions.

The result of a calibration is an instrument sensitivity accompanied by an uncertainty. This document offers suggestions for uncertainty evaluation in the annexes.

Edition

2

Published Date

2023-01-20

Status

PUBLISHED

Pages

32

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies two preferred methods for the calibration of pyranometers using reference pyranometers; indoor (Type A) and outdoor (Type B).

Indoor or type A calibration, is performed against a lamp source, while the outdoor method B, employs natural solar radiation as the source.

Indoor calibration is performed either at normal incidence (type A1), the receiver surface perpendicular to the beam of the lamp or under exposure to a uniform diffuse lamp source using an integrating sphere (type A2).

Outdoor calibration is performed using the sun as a source, with the pyranometer in a horizontal position (type B1), in a tilted position (type B2), or at normal incidence (type B3).

Calibrations according to the specified methods will be traceable to SI, through the world radiometric reference (WRR), provided that traceable reference instruments are used.

This document is applicable to most types of pyranometers regardless of the type technology employed. The methods have been validated for pyranometers that comply with the requirements for classes A, B and C of ISO 9060. In general, all pyranometers may be calibrated by using the described methods, provided that a proper uncertainty evaluation is performed.

Unlike spectrally flat pyranometers, non-spectrally flat pyranometers might have a spectral response that varies strongly with the wavelength even within the spectral range from 300 to 1 500 nm, and therefore the calibration result may possibly be valid under a more limited range of conditions.

The result of a calibration is an instrument sensitivity accompanied by an uncertainty. This document offers suggestions for uncertainty evaluation in the annexes.