CSA C2.1:24
CSA C2.1:24 – Single-phase and three-phase liquid-filled distribution transformers
CDN $284.00
Single-phase and three-phase liquid-filled distribution transformers
Description
Preface This is the second edition of CSA C2.1, Single-phase and three-phase liquid-filled distribution transformers. It supersedes the previous edition published in 2006 and previous editions of CSA C2, Single-Phase and Three-Phase Liquid-filled Distribution Transformers, Types ONAN and LNAN, published in 1991, 1982, 1976, 1969, 1959, 1944, 1928, and 1920. This edition includes requirements for single-phase, single-bushing, 60 Hz distribution transformers suitable for direct pole mounting and designed for operation on an effectively grounded wye system, Type ONAN, rated at 167 kVA or below, up to 34.5 kV system nominal voltage. Changes to this edition include updates to various clauses, tables, figures, and annexes to reflect minimum industry requirements. This Standard specifies the requirements for distribution transformers intended primarily for operation by electric utilities. The operation of transformers complying with this Standard by other than an electric utility could be subject to additional requirements by the electrical inspection regulatory authority having jurisdiction. CSA Group acknowledges that the development of this Standard was made possible, in part, by the financial support of Alectra Utilities, Electricity Canada (EC), EPCOR, FortisAlberta, FortisBC, Hydro One, Hydro-Québec, IFD Corp., K-Line Insulators Ltd., Maritime Electric, NB Power, Newfoundland and Labrador Hydro, Newfoundland Power, Nova Scotia Power, S&C Electric Canada Ltd., Schneider Electric Canada Inc., Toronto Hydro, and Utilities Standards Forum (USF). This Standard was prepared by the Subcommittee on Overhead and Pad-Mounted Distribution Transformers, under the jurisdiction of the Technical Committee on Distribution Transformers and the Strategic Steering Committee on Power Engineering and Electromagnetic Compatibility, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 Inclusions This Standard specifies the requirements for distribution transformers except for those distribution transformers covered by CSA C2.2, CSA C227.3, and CSA C227.4. Note: The operation of transformers complying with this Standard by other than an electric utility might be subject to additional requirements by the electrical inspection authority having jurisdiction. 1.2 Ratings This Standard applies to single- and three-phase, 60 Hz, liquid-filled distribution transformers rated at 1000 kVA or below for single-phase, and at 3000 kVA or below for three-phase, up to 34.5 kV system nominal voltage. 1.3 Performance characteristics This Standard includes voltage ratings, kVA ratings, certain mechanical characteristics, and test procedures. It also includes the following performance characteristics: energy efficiency (in accordance with CSA C802.1), temperature rise, loading capabilities, sound level, and radio influence voltage (RIV). 1.4 Self-protected transformers This Standard also applies to self-protected transformers with the exception of protective equipment. 1.5 Exceptions Except as specified by other CSA Standards, this Standard does not apply to auto-, testing, dry-type, welding, furnace, rectifier, network, subway, or special-purpose transformers, or to step-voltage regulators. 1.6 Units of measurement The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only. 1.7 Terminology In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
74
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the second edition of CSA C2.1, Single-phase and three-phase liquid-filled distribution transformers. It supersedes the previous edition published in 2006 and previous editions of CSA C2, Single-Phase and Three-Phase Liquid-filled Distribution Transformers, Types ONAN and LNAN, published in 1991, 1982, 1976, 1969, 1959, 1944, 1928, and 1920. This edition includes requirements for single-phase, single-bushing, 60 Hz distribution transformers suitable for direct pole mounting and designed for operation on an effectively grounded wye system, Type ONAN, rated at 167 kVA or below, up to 34.5 kV system nominal voltage. Changes to this edition include updates to various clauses, tables, figures, and annexes to reflect minimum industry requirements. This Standard specifies the requirements for distribution transformers intended primarily for operation by electric utilities. The operation of transformers complying with this Standard by other than an electric utility could be subject to additional requirements by the electrical inspection regulatory authority having jurisdiction. CSA Group acknowledges that the development of this Standard was made possible, in part, by the financial support of Alectra Utilities, Electricity Canada (EC), EPCOR, FortisAlberta, FortisBC, Hydro One, Hydro-Québec, IFD Corp., K-Line Insulators Ltd., Maritime Electric, NB Power, Newfoundland and Labrador Hydro, Newfoundland Power, Nova Scotia Power, S&C Electric Canada Ltd., Schneider Electric Canada Inc., Toronto Hydro, and Utilities Standards Forum (USF). This Standard was prepared by the Subcommittee on Overhead and Pad-Mounted Distribution Transformers, under the jurisdiction of the Technical Committee on Distribution Transformers and the Strategic Steering Committee on Power Engineering and Electromagnetic Compatibility, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 Inclusions This Standard specifies the requirements for distribution transformers except for those distribution transformers covered by CSA C2.2, CSA C227.3, and CSA C227.4. Note: The operation of transformers complying with this Standard by other than an electric utility might be subject to additional requirements by the electrical inspection authority having jurisdiction. 1.2 Ratings This Standard applies to single- and three-phase, 60 Hz, liquid-filled distribution transformers rated at 1000 kVA or below for single-phase, and at 3000 kVA or below for three-phase, up to 34.5 kV system nominal voltage. 1.3 Performance characteristics This Standard includes voltage ratings, kVA ratings, certain mechanical characteristics, and test procedures. It also includes the following performance characteristics: energy efficiency (in accordance with CSA C802.1), temperature rise, loading capabilities, sound level, and radio influence voltage (RIV). 1.4 Self-protected transformers This Standard also applies to self-protected transformers with the exception of protective equipment. 1.5 Exceptions Except as specified by other CSA Standards, this Standard does not apply to auto-, testing, dry-type, welding, furnace, rectifier, network, subway, or special-purpose transformers, or to step-voltage regulators. 1.6 Units of measurement The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only. 1.7 Terminology In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CAN/CSA-E61965:04 (R2023) – Mechanical safety of cathode ray tubes (Adopted IEC 61965:2003, second edition, 2003-07, with Canadian deviations)
CDN $356.00 Add to cart -

IEEE 844.4-2019/CSA C293.4:19 (R2024) – Impedance heating of pipelines and equipment—Application guide for design, installation, testing, commissioning, and maintenance
CDN $174.00 Add to cart -

IEEE 844.1-2017/CSA C22.2 NO. 293.1:17 (R2022) – Skin effect trace heating of pipelines, vessels, equipment, and structures—General, testing, marking, and documentation requirements
CDN $158.00 Add to cart -

CSA E61558-2-5:25 – Safety of transformers, reactors, power supply units and combinations thereof — Part 2-5: Particular requirements and tests for transformers for shavers, power supply units for shavers and shaver supply units (Adopted IEC 61558-2-5:2024, third edition, 2024-08, with Canadian deviations) | Sécurité des transformateurs, bobines d’inductance, blocs d’alimentation et combinaisons de ces éléments — Partie 2-5 : Exigences particulières et essais pour les transformateurs pour rasoirs, les blocs d’alimentation incorporant un transformateur pour rasoir et les blocs d’alimentation pour rasoirs (norme IEC 61558-2-5:2024 adoptée, troisième édition, 2024-08, avec exigences propres au Canada)
CDN $299.00 Add to cart