CSA C22.2 NO. 178.1:22
CSA C22.2 NO. 178.1:22 – Transfer switch equipment (Trinational standard with NMX-J-674-ANCE and UL 1008)
CDN $925.00
Transfer switch equipment (Trinational standard with NMX-J-674-ANCE and UL 1008)
Description
Preface This is the harmonized CSA Group and ULSE standard for Transfer Switch Equipment . It is the fourth edition of CSA C22.2 No. 178.1 and the ninth edition of UL 1008. This edition of CSA C22.2 No. 178.1 supersedes the previous edition published on December 22, 2014 and revised on September 24, 2018. This edition of UL 1008 supersedes the previous edition published on December 22, 2014 and revised on September 24, 2018. This harmonized standard has been jointly revised on August 25, 2026. For this purpose, CSA Group and ULSE are issuing revision pages dated August 25, 2026. This harmonized standard was prepared by CSA Group and ULSE Inc. (ULSE). The efforts and support of the Technical Harmonization Subcommittee for Transfer Switches and the Council of the Harmonization of Electrotechnical Standards for the Nations of the Americas (CANENA), are gratefully acknowledged. This standard is considered suitable for use for conformity assessment within the stated scope of the standard. While ANCE continues to participate in the technical development of this trinational standard, the ANCE logo has been removed from the title page as standards cannot be formally published in Mexico at this time. This standard was reviewed by the CSA Subcommittee on Automatic Transfer Switches, under the jurisdiction of the CSA Technical Committee on Industrial Products and the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the CSA Technical Committee. This standard has been developed in compliance with the Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This standard applies to the following types of transfer switches that have a maximum rating of 1000 volts for use in non-hazardous locations, in accordance with Annex A1, Item 1: a) Automatic transfer switches; b) Manual or non-automatic transfer switches; c) Closed transition transfer switches; d) Hybrid transfer switches; e) Transfer switches for fire pumps; f) Bypass/isolating switches; g) Softload transfer switches; h) Transfer switches intended for use as service equipment; i) Transfer switches intended for use in mobile/portable applications such as recreational vehicles, motor homes, camping trailers, and mobile health care facilities; j) Inlet assemblies for transfer switch equipment; k) Arc resistant transfer switch equipment; l) Cord connected transfer switch equipment; m) Combination meter/transfer equipment assemblies; and n) In Mexico and the United States, branch circuit emergency lighting transfer switches (BCELTS). In Canada, the requirements for BCELTS do not apply. 1.2 This standard specifically does not apply to: a) Double-throw switches for use in optional standby systems; b) Switches used in equipment manufactured in accordance with Annex A1, Item 9; c) In Canada, manually operated generator transfer panels in accordance with Annex A1, Item 12. d) Transfer switches rated over 1000 V; e) Solid-state (static) transfer equipment; f) Transfer switches for aircraft; and g) Transfer switches for water craft. 1.3 These requirements apply to transfer switches and their associated control devices including voltage sensing relays, frequency sensing relays, time-delay relays, and the like. 1.4 These requirements apply to completely enclosed transfer switches and to open types intended for mounting in other equipment such as switchboards. 1.5 These requirements apply to bypass/isolation switches used to manually select an available power source to feed load circuits and to provide for total isolation of an automatic transfer switch. These switches may be completely enclosed, enclosed with the transfer switch, or of the open type intended for mounting in other equipment. Refer to Annex D. 1.6 In Canada, automatic transfer switches built to the optional standby requirements of this standard are not permitted. In Mexico and the United States, this requirement does not apply. 1.7 These requirements cover enclosed inlets intended to facilitate connection of portable generators to transfer equipment. 1.8 This Standard contains annexes with requirements to cover the following: a) Bypass/isolation switches (Annex D) b) Transfer switches for fire pump service (Annex E) c) Hybrid transfer switches (Annex F) d) Softload transfer switches (Annex G) e) Instrumentation and calibration of high capacity circuits (Annex H) f) Sample markings (Annex I) g) Inlet assemblies for transfer switch equipment (Annex J) h) Arc resistant transfer switch equipment (Annex K) i) Electromagnetic compatibility (EMC) requirements for transfer switches (Annex L) j) Cord connected transfer switch equipment (Annex M) k) Combination meter/transfer equipment assemblies (Annex N)
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
243
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the harmonized CSA Group and ULSE standard for Transfer Switch Equipment . It is the fourth edition of CSA C22.2 No. 178.1 and the ninth edition of UL 1008. This edition of CSA C22.2 No. 178.1 supersedes the previous edition published on December 22, 2014 and revised on September 24, 2018. This edition of UL 1008 supersedes the previous edition published on December 22, 2014 and revised on September 24, 2018. This harmonized standard has been jointly revised on August 25, 2026. For this purpose, CSA Group and ULSE are issuing revision pages dated August 25, 2026. This harmonized standard was prepared by CSA Group and ULSE Inc. (ULSE). The efforts and support of the Technical Harmonization Subcommittee for Transfer Switches and the Council of the Harmonization of Electrotechnical Standards for the Nations of the Americas (CANENA), are gratefully acknowledged. This standard is considered suitable for use for conformity assessment within the stated scope of the standard. While ANCE continues to participate in the technical development of this trinational standard, the ANCE logo has been removed from the title page as standards cannot be formally published in Mexico at this time. This standard was reviewed by the CSA Subcommittee on Automatic Transfer Switches, under the jurisdiction of the CSA Technical Committee on Industrial Products and the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the CSA Technical Committee. This standard has been developed in compliance with the Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This standard applies to the following types of transfer switches that have a maximum rating of 1000 volts for use in non-hazardous locations, in accordance with Annex A1, Item 1: a) Automatic transfer switches; b) Manual or non-automatic transfer switches; c) Closed transition transfer switches; d) Hybrid transfer switches; e) Transfer switches for fire pumps; f) Bypass/isolating switches; g) Softload transfer switches; h) Transfer switches intended for use as service equipment; i) Transfer switches intended for use in mobile/portable applications such as recreational vehicles, motor homes, camping trailers, and mobile health care facilities; j) Inlet assemblies for transfer switch equipment; k) Arc resistant transfer switch equipment; l) Cord connected transfer switch equipment; m) Combination meter/transfer equipment assemblies; and n) In Mexico and the United States, branch circuit emergency lighting transfer switches (BCELTS). In Canada, the requirements for BCELTS do not apply. 1.2 This standard specifically does not apply to: a) Double-throw switches for use in optional standby systems; b) Switches used in equipment manufactured in accordance with Annex A1, Item 9; c) In Canada, manually operated generator transfer panels in accordance with Annex A1, Item 12. d) Transfer switches rated over 1000 V; e) Solid-state (static) transfer equipment; f) Transfer switches for aircraft; and g) Transfer switches for water craft. 1.3 These requirements apply to transfer switches and their associated control devices including voltage sensing relays, frequency sensing relays, time-delay relays, and the like. 1.4 These requirements apply to completely enclosed transfer switches and to open types intended for mounting in other equipment such as switchboards. 1.5 These requirements apply to bypass/isolation switches used to manually select an available power source to feed load circuits and to provide for total isolation of an automatic transfer switch. These switches may be completely enclosed, enclosed with the transfer switch, or of the open type intended for mounting in other equipment. Refer to Annex D. 1.6 In Canada, automatic transfer switches built to the optional standby requirements of this standard are not permitted. In Mexico and the United States, this requirement does not apply. 1.7 These requirements cover enclosed inlets intended to facilitate connection of portable generators to transfer equipment. 1.8 This Standard contains annexes with requirements to cover the following: a) Bypass/isolation switches (Annex D) b) Transfer switches for fire pump service (Annex E) c) Hybrid transfer switches (Annex F) d) Softload transfer switches (Annex G) e) Instrumentation and calibration of high capacity circuits (Annex H) f) Sample markings (Annex I) g) Inlet assemblies for transfer switch equipment (Annex J) h) Arc resistant transfer switch equipment (Annex K) i) Electromagnetic compatibility (EMC) requirements for transfer switches (Annex L) j) Cord connected transfer switch equipment (Annex M) k) Combination meter/transfer equipment assemblies (Annex N)
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

IEEE 844.4-2019/CSA C293.4:19 (R2024) – Impedance heating of pipelines and equipment—Application guide for design, installation, testing, commissioning, and maintenance
CDN $174.00 Add to cart -

CSA E61558-2-5:25 – Safety of transformers, reactors, power supply units and combinations thereof — Part 2-5: Particular requirements and tests for transformers for shavers, power supply units for shavers and shaver supply units (Adopted IEC 61558-2-5:2024, third edition, 2024-08, with Canadian deviations) | Sécurité des transformateurs, bobines d’inductance, blocs d’alimentation et combinaisons de ces éléments — Partie 2-5 : Exigences particulières et essais pour les transformateurs pour rasoirs, les blocs d’alimentation incorporant un transformateur pour rasoir et les blocs d’alimentation pour rasoirs (norme IEC 61558-2-5:2024 adoptée, troisième édition, 2024-08, avec exigences propres au Canada)
CDN $299.00 Add to cart -

CSA C22.3 NO. 5.1:93 (R2022) – Recommended practices for electrical protection – Electric contact between overhead supply and communication lines
CDN $149.00 Add to cart -

CSA E62660-1:21 (R2026) – Secondary lithium-ion cells for the propulsion of electric road vehicles – Part 1: Performance testing (Adopted IEC 62660-1:2018, second edition, 2018-12, with Canadian deviations) | Éléments d’accumulateurs lithium-ion pour la propulsion des véhicules routiers électriques – Partie 1 : Essais de performance (norme IEC 62660-1:2018 adoptée, deuxième édition, 2018-12, avec exigences propres au Canada)
CDN $436.00 Add to cart