Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA C22.2 NO. 182.2:M87 (R2023)

CSA C22.2 NO. 182.2:M87 (R2023) – Industrial Locking Type, Special Use Attachment Plugs, Receptacles and Connectors

CDN $164.00

Industrial Locking Type, Special Use Attachment Plugs, Receptacles and Connectors

SKU: 2411176 Categories: ,

Description

Preface This is the first edition of No. 182.2 of a series of Standards issued by the Canadian Standards Association under Part II of the Canadian Electrical Code. It is written in SI (metric) units. This Standard applies to locking type plugs, receptacles, equipment power inlets and outlets, and connectors rated up to 60 A and up to 600 V ac or 250 V dc, for use in accordance with the Canadian Electrical Code, Part I. This standard also applies to “hospital only” locking type plugs, connectors, and receptacles. For general information on the Standards of the Canadian Electrical Code, Part II, see the preface of CSA Standard C22.2 No. 0, General Requirements—Canadian Electrical Code, Part II. This Standard was prepared by a Subcommittee of the Technical Committee on Wiring Products under the jurisdiction of the Standards Steering Committee on Canadian Electrical Code, Part II, and was formally approved by these Committees. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to locking type plugs, receptacles, equipment power inlets and outlets, and connectors rated up to 60 A and up to 600 V ac or 250 V dc, for use in accordance with the Canadian Electrical Code, Part I. 1.2 The devices covered by this Standard are intended for use with copper conductors only in making readily detachable electrical connections utilizing a variety of current and voltage ratings. 1.3 This Standard also applies to “hospital only”, locking type plugs, connectors, and receptacles. 1.4 This Standard does not apply to (a) pull-off plugs covered in CSA Standard C22.2 No. 57; (b) receptacles, attachment plugs, connectors, and adapters intended for use in hazardous locations that are covered in CSA Standard C22.2 No. 159; (c) general use attachment plugs, receptacles, and similar wiring devices covered in CSA Standard C22.2 No. 42; and (d) industrial type, special use attachment plugs, receptacles, equipment power inlets and outlets, and connectors covered in CSA Standard C22.2 No. 182.1; or (e) special use attachment plugs, receptacles, equipment power inlets, and connectors covered in CSA Standard C22.2 No. 182.3.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

46

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the first edition of No. 182.2 of a series of Standards issued by the Canadian Standards Association under Part II of the Canadian Electrical Code. It is written in SI (metric) units. This Standard applies to locking type plugs, receptacles, equipment power inlets and outlets, and connectors rated up to 60 A and up to 600 V ac or 250 V dc, for use in accordance with the Canadian Electrical Code, Part I. This standard also applies to "hospital only" locking type plugs, connectors, and receptacles. For general information on the Standards of the Canadian Electrical Code, Part II, see the preface of CSA Standard C22.2 No. 0, General Requirements—Canadian Electrical Code, Part II. This Standard was prepared by a Subcommittee of the Technical Committee on Wiring Products under the jurisdiction of the Standards Steering Committee on Canadian Electrical Code, Part II, and was formally approved by these Committees. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to locking type plugs, receptacles, equipment power inlets and outlets, and connectors rated up to 60 A and up to 600 V ac or 250 V dc, for use in accordance with the Canadian Electrical Code, Part I. 1.2 The devices covered by this Standard are intended for use with copper conductors only in making readily detachable electrical connections utilizing a variety of current and voltage ratings. 1.3 This Standard also applies to "hospital only", locking type plugs, connectors, and receptacles. 1.4 This Standard does not apply to (a) pull-off plugs covered in CSA Standard C22.2 No. 57; (b) receptacles, attachment plugs, connectors, and adapters intended for use in hazardous locations that are covered in CSA Standard C22.2 No. 159; (c) general use attachment plugs, receptacles, and similar wiring devices covered in CSA Standard C22.2 No. 42; and (d) industrial type, special use attachment plugs, receptacles, equipment power inlets and outlets, and connectors covered in CSA Standard C22.2 No. 182.1; or (e) special use attachment plugs, receptacles, equipment power inlets, and connectors covered in CSA Standard C22.2 No. 182.3.

Previous Editions

Can’t find what you are looking for?

Please contact us at: