CSA C22.2 NO. 60601-1-10:09 + A1:14 (R2020) + A2:21 (CONSOLIDATED)
CSA C22.2 NO. 60601-1-10:09 + A1:14 (R2020) + A2:21 (CONSOLIDATED) – Medical electrical equipment — Part 1-10: General requirements for basic safety and essential performance — Collateral Standard: Requirements for the development of physiologic closed-loop controllers (Adopted IEC 60601-1-10:2007, edition 1:2007 consolidated with amendment 1:2013 and amendment 2:2020, with Canadian deviations) | Appareils électromédicaux — Partie 1-10 : Exigences générales pour la sécurité de base et les performances essentielles — Norme collatérale : Exigences pour le développement des régulateurs physiologiques en boucle fermée (norme IEC 60601-1-10:2007 adoptée, édition 1:2007 consolidée par l’amendement 1:2013 et l’amendement 2:2020, avec exigences propres au Canada)
CDN $811.00
Medical electrical equipment — Part 1-10: General requirements for basic safety and essential performance — Collateral Standard: Requirements for the development of physiologic closed-loop controllers (Adopted IEC 60601-1-10:2007, edition 1:2007 consolidated with amendment 1:2013 and amendment 2:2020, with Canadian deviations) | Appareils électromédicaux — Partie 1-10 : Exigences générales pour la sécurité de base et les performances essentielles — Norme collatérale : Exigences pour le développement des régulateurs physiologiques en boucle fermée (norme IEC 60601-1-10:2007 adoptée, édition 1:2007 consolidée par l’amendement 1:2013 et l’amendement 2:2020, avec exigences propres au Canada)
Description
CSA Preface This is consolidated edition 1.2 of CSA C22.2 No. 60601-1-10, Medical electrical equipment — Part 1-10: General requirements for basic safety and essential performance — Collateral Standard: Requirements for the development of physiologic closed-loop controllers , which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 60601-1-10 (edition 1:2007 consolidated with Amendment 1:2013 and Amendment 2:2020). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For brevity, this Standard will be referred to as “CSA C22.2 No. 60601-1-10,” throughout. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 60601-1:14, Medical electrical equipment — Part 1: General requirements for basic safety and essential performance (adopted IEC 60601-1:2005, including Amendment 1:2012, with Canadian deviations). Where differences exist between this consolidated edition and the published edition and its amendments, those documents will take precedence. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope and object 1.1 * Scope This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL ELECTRICAL EQUIPMENT and MEDICAL ELECTRICAL SYSTEMS, hereafter referred to as ME EQUIPMENT and ME SYSTEMS. This collateral standard specifies requirements for the development (analysis, design, VERIFICATION and VALIDATION) of a PHYSIOLOGIC CLOSED-LOOP CONTROLLER (PCLC) as part of a PHYSIOLOGIC CLOSED-LOOP CONTROL SYSTEM (PCLCS) to control at least one PATIENT VARIABLE (i.e. a PHYSIOLOGIC VARIABLE) in ME EQUIPMENT and ME SYSTEMS. EXAMPLE A PATIENT VARIABLE can be a measure of body chemistry (e.g. electrolytes or blood glucose value), a physical property (e.g. body temperature, electrophysiologic characteristic, hemodynamic quantity), or a pharmaceutical concentration. This collateral standard applies to various types of PCLC, e.g. linear and non-linear, adaptive, fuzzy, neural networks. This collateral standard does not specify: − additional mechanical requirements; or − additional electrical requirements. This collateral standard applies to a closed-loop controller (see Figure 1) that sets the CONTROLLER OUTPUT VARIABLE in order to adjust (i.e., change or maintain) the measured PHYSIOLOGIC VARIABLE by relating it to the REFERENCE VARIABLE. A closed-loop controller that maintains a physical or chemical VARIABLE, using feedback that is not measured from a PATIENT, is outside the scope of this standard. 1.2 Object The object of this collateral standard is to specify general requirements that are in addition to those of the general standard and to serve as the basis for particular standards. ——————————————————————————————————————————– Préface CSA Ce document constitue l’édition 1.2 consolidée de CSA C22.2 nº 60601-1-10, Appareils électromédicaux — Partie 1-10 : Exigences générales pour la sécurité de base et les performances essentielles — Norme collatérale : Exigences pour le développement des régulateurs physiologiques en boucle fermée . Il s’agit de l’adoption, avec exigences propres au Canada, de la norme IEC (Commission Électrotechnique Internationale) 60601-1-10 (édition 1:2007 consolidée par l’amendement 1:2013 et l’amendement 2:2020), qui porte le même titre. Il fait partie d’une série de normes publiées par Groupe CSA qui constituent le Code canadien de l’électricité, Deuxième partie. Par souci de brièveté, tout au long de ce document, il sera appelé « CSA C22.2 nº 60601-1-10 ». Cette norme est conçue pour être utilisée de concert avec la norme CAN/CSA-C22.2 nº 60601-1:14, Appareils électromédicaux — Partie 1 : Exigences générales pour la sécurité de base et les performances essentielles (norme IEC 60601-1:2005 adoptée, avec exigences propres au Canada, y compris l’amendement 1:2012). Lorsqu’il y a des différences entre cette édition consolidée et l’édition publiée et ses amendements, ces derniers auront préséance. Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes relatives aux Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d’application et objet 1.1 * Domaine d’application La présente Norme internationale s’applique à la SECURITE DE BASE et aux PERFORMANCES ESSENTIELLES des APPAREILS ELECTROMEDICAUX et des SYSTEMES ELECTROMEDICAUX, désignés ci-après sous le terme APPAREILS EM et SYSTEMES EM. La présente norme collatérale spécifie les exigences pour le développement (analyse, conception, VERIFICATION et VALIDATION) d’un REGULATEUR PHYSIOLOGIQUE EN BOUCLE FERMEE (RPBF) en tant que partie d’un SYSTEME PHYSIOLOGIQUE DE COMMANDE EN BOUCLE FERMEE (SPCBF) pour contrôler au moins une VARIABLE PATIENT (c’est-à-dire une VARIABLE PHYSIOLOGIQUE) dans les APPAREILS EM et les SYSTEMES EM. EXEMPLE Une VARIABLE PATIENT peut être une mesure du produit chimique du corps (par exemple valeur des électrolytes ou de la glycémie), une propriété physique (par exemple température du corps, caractéristique électrophysiologique, grandeur hémodynamique) ou un soluté pharmaceutique. La présente norme collatérale s’applique aux différents types de RPBF, par exemple linéaire et non-linéaire, adaptatifs, fuzzy, réseaux de neurones. La présente norme collatérale ne spécifie pas – des exigences mécaniques additionnelles; ou – des exigences électriques additionnelles. La présente norme collatérale s’applique à un régulateur en boucle fermée (voir Figure 1) qui règle la VARIABLE DE SORTIE DU REGULATEUR afin d’ajuster (c’est-à-dire, changer ou maintenir) la VARIABLE PHYSIOLOGIQUE mesurée en effectuant une comparaison avec la VARIABLE DE REFERENCE. Un régulateur en boucle fermée qui maintient une VARIABLE physique ou chimique en utilisant une réaction dont la mesure n’a pas de liaison avec le PATIENT, ne fait pas partie du domaine d’application de la présente norme. 1.2 Objet La présente norme collatérale est destinée à spécifier des exigences générales qui viennent compléter celles de la norme générale et à servir de base pour les normes particulières.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
197
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
CSA Preface This is consolidated edition 1.2 of CSA C22.2 No. 60601-1-10, Medical electrical equipment — Part 1-10: General requirements for basic safety and essential performance — Collateral Standard: Requirements for the development of physiologic closed-loop controllers , which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 60601-1-10 (edition 1:2007 consolidated with Amendment 1:2013 and Amendment 2:2020). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For brevity, this Standard will be referred to as "CSA C22.2 No. 60601-1-10," throughout. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 60601-1:14, Medical electrical equipment — Part 1: General requirements for basic safety and essential performance (adopted IEC 60601-1:2005, including Amendment 1:2012, with Canadian deviations). Where differences exist between this consolidated edition and the published edition and its amendments, those documents will take precedence. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope and object 1.1 * Scope This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL ELECTRICAL EQUIPMENT and MEDICAL ELECTRICAL SYSTEMS, hereafter referred to as ME EQUIPMENT and ME SYSTEMS. This collateral standard specifies requirements for the development (analysis, design, VERIFICATION and VALIDATION) of a PHYSIOLOGIC CLOSED-LOOP CONTROLLER (PCLC) as part of a PHYSIOLOGIC CLOSED-LOOP CONTROL SYSTEM (PCLCS) to control at least one PATIENT VARIABLE (i.e. a PHYSIOLOGIC VARIABLE) in ME EQUIPMENT and ME SYSTEMS. EXAMPLE A PATIENT VARIABLE can be a measure of body chemistry (e.g. electrolytes or blood glucose value), a physical property (e.g. body temperature, electrophysiologic characteristic, hemodynamic quantity), or a pharmaceutical concentration. This collateral standard applies to various types of PCLC, e.g. linear and non-linear, adaptive, fuzzy, neural networks. This collateral standard does not specify: − additional mechanical requirements; or − additional electrical requirements. This collateral standard applies to a closed-loop controller (see Figure 1) that sets the CONTROLLER OUTPUT VARIABLE in order to adjust (i.e., change or maintain) the measured PHYSIOLOGIC VARIABLE by relating it to the REFERENCE VARIABLE. A closed-loop controller that maintains a physical or chemical VARIABLE, using feedback that is not measured from a PATIENT, is outside the scope of this standard. 1.2 Object The object of this collateral standard is to specify general requirements that are in addition to those of the general standard and to serve as the basis for particular standards. -------------------------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue l’édition 1.2 consolidée de CSA C22.2 nº 60601-1-10, Appareils électromédicaux — Partie 1-10 : Exigences générales pour la sécurité de base et les performances essentielles — Norme collatérale : Exigences pour le développement des régulateurs physiologiques en boucle fermée . Il s’agit de l’adoption, avec exigences propres au Canada, de la norme IEC (Commission Électrotechnique Internationale) 60601-1-10 (édition 1:2007 consolidée par l’amendement 1:2013 et l’amendement 2:2020), qui porte le même titre. Il fait partie d’une série de normes publiées par Groupe CSA qui constituent le Code canadien de l’électricité, Deuxième partie. Par souci de brièveté, tout au long de ce document, il sera appelé « CSA C22.2 nº 60601-1-10 ». Cette norme est conçue pour être utilisée de concert avec la norme CAN/CSA-C22.2 nº 60601-1:14, Appareils électromédicaux — Partie 1 : Exigences générales pour la sécurité de base et les performances essentielles (norme IEC 60601-1:2005 adoptée, avec exigences propres au Canada, y compris l’amendement 1:2012). Lorsqu’il y a des différences entre cette édition consolidée et l’édition publiée et ses amendements, ces derniers auront préséance. Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes relatives aux Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d'application et objet 1.1 * Domaine d’application La présente Norme internationale s'applique à la SECURITE DE BASE et aux PERFORMANCES ESSENTIELLES des APPAREILS ELECTROMEDICAUX et des SYSTEMES ELECTROMEDICAUX, désignés ci-après sous le terme APPAREILS EM et SYSTEMES EM. La présente norme collatérale spécifie les exigences pour le développement (analyse, conception, VERIFICATION et VALIDATION) d'un REGULATEUR PHYSIOLOGIQUE EN BOUCLE FERMEE (RPBF) en tant que partie d'un SYSTEME PHYSIOLOGIQUE DE COMMANDE EN BOUCLE FERMEE (SPCBF) pour contrôler au moins une VARIABLE PATIENT (c’est-à-dire une VARIABLE PHYSIOLOGIQUE) dans les APPAREILS EM et les SYSTEMES EM. EXEMPLE Une VARIABLE PATIENT peut être une mesure du produit chimique du corps (par exemple valeur des électrolytes ou de la glycémie), une propriété physique (par exemple température du corps, caractéristique électrophysiologique, grandeur hémodynamique) ou un soluté pharmaceutique. La présente norme collatérale s'applique aux différents types de RPBF, par exemple linéaire et non-linéaire, adaptatifs, fuzzy, réseaux de neurones. La présente norme collatérale ne spécifie pas – des exigences mécaniques additionnelles; ou – des exigences électriques additionnelles. La présente norme collatérale s'applique à un régulateur en boucle fermée (voir Figure 1) qui règle la VARIABLE DE SORTIE DU REGULATEUR afin d'ajuster (c'est-à-dire, changer ou maintenir) la VARIABLE PHYSIOLOGIQUE mesurée en effectuant une comparaison avec la VARIABLE DE REFERENCE. Un régulateur en boucle fermée qui maintient une VARIABLE physique ou chimique en utilisant une réaction dont la mesure n'a pas de liaison avec le PATIENT, ne fait pas partie du domaine d'application de la présente norme. 1.2 Objet La présente norme collatérale est destinée à spécifier des exigences générales qui viennent compléter celles de la norme générale et à servir de base pour les normes particulières.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA E61558-2-5:25 – Safety of transformers, reactors, power supply units and combinations thereof — Part 2-5: Particular requirements and tests for transformers for shavers, power supply units for shavers and shaver supply units (Adopted IEC 61558-2-5:2024, third edition, 2024-08, with Canadian deviations) | Sécurité des transformateurs, bobines d’inductance, blocs d’alimentation et combinaisons de ces éléments — Partie 2-5 : Exigences particulières et essais pour les transformateurs pour rasoirs, les blocs d’alimentation incorporant un transformateur pour rasoir et les blocs d’alimentation pour rasoirs (norme IEC 61558-2-5:2024 adoptée, troisième édition, 2024-08, avec exigences propres au Canada)
CDN $299.00 Add to cart -

CSA E61951-1:21 (R2026) – Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 1: Nickel-cadmium (Adopted IEC 61951:2017, fourth edition, 2017-03, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide — Accumulateurs étanches pour applications portables — Partie 1 : Nickel-cadmium (norme IEC 61951-1:2017 adoptée, quatrième édition, 2017-03), avec exigences propres au Canada)
CDN $527.00 Add to cart -

CSA E61951-2:21 (R2026) – Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 2: Nickel-metal hydride (Adopted IEC 61951-2:2017, fourth edition, 2017-03, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide — Accumulateurs étanches pour applications portables — Partie 2 : Nickel-métal hydrure (norme IEC 61951-2:2017 adoptée, quatrième édition, 2017-03, avec exigences propres au Canada)
CDN $527.00 Add to cart -

CSA E62660-2:21 (R2026) – Secondary lithium-ion cells for the propulsion of electric road vehicles – Part 2: Reliability and abuse testing (Adopted IEC 62660-2:2018, second edition, 2018-12, with Canadian deviations) | Éléments d’accumulateurs lithium-ion pour la propulsion des véhicules routiers électriques – Partie 2 : Essais de fiabilité et de traitement abusif (norme IEC 62660-2:2018 adoptée, deuxième édition, 2018-12, avec exigences propres au Canada)
CDN $225.00 Add to cart