
CSA C22.2 NO. 60601-1-3:09 (R2024)
CSA C22.2 NO. 60601-1-3:09 (R2024) – Medical electrical equipment – Part 1-3: General requirements for basic safety and essential performance – Collateral standard: Radiation protection in diagnostic X-ray equipment (Adopted IEC 60601-1:2008, second edition, 2008-01) | Appareils électromédicaux – Partie 1-3: Exigences générales pour la sécurité de base et les performances essentielles – Norme collatérale: Radioprotection dans les appareils à rayonnement X de diagnostic (norme IEC 60601-1:2008 adoptée, deuxième édition, 2008-01)
CDN $364.00
Medical electrical equipment – Part 1-3: General requirements for basic safety and essential performance – Collateral standard: Radiation protection in diagnostic X-ray equipment (Adopted IEC 60601-1:2008, second edition, 2008-01) | Appareils électromédicaux – Partie 1-3: Exigences générales pour la sécurité de base et les performances essentielles – Norme collatérale: Radioprotection dans les appareils à rayonnement X de diagnostic (norme IEC 60601-1:2008 adoptée, deuxième édition, 2008-01)
Description
CSA Preface This is the second edition of CAN/CSA-C22.2 No. 60601-1-3, Medical electrical equipment – Part 1-3: General requirements for basic safety and essential performance – Collateral Standard: Radiation protection in diagnostic X-ray equipment , which is an adoption without modification of the identically titled IEC (International Electrotechnical Commission) Standard 60601-1-3 (second edition, 2008-01). It supersedes the previous edition published in 1998 as CAN/CSA-C22.2 No. 601.1.3 (adopted CEI/IEC 601-1-3:1994). It is one in a series of Standards issued by CSA under Part II of the Canadian Electrical Code. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 60601-1:08, Medical electrical equipment — Part 1: General requirements for basic safety and essential performance (adopted IEC 60601-1:2005, with Canadian deviations). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on Consumer and Commercial Products, under the jurisdiction of the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. Due to the medical content of this Standard, it was also approved by the CSA Technical Committee on Applications of Electricity in Health Care under the jurisdiction of the Strategic Steering Committee on Health Care Technology. This Standard has been approved as a National Standard of Canada by the Standards Council of Canada. Scope, object and related standards 1.1 Scope This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL ELECTRICAL EQUIPMENT and MEDICAL ELECTRICAL SYSTEMS, hereafter referred to as ME EQUIPMENT and ME SYSTEMS. This collateral standard applies to X-RAY EQUIPMENT and to subassemblies of such equipment, where RADIOLOGICAL IMAGES of a human PATIENT are used for diagnosis, planning or guidance of medical procedures. 1.2 Object The object of this collateral standard is to specify general requirements that are in addition to those of the general standard and to serve as the basis for particular standards. The object of this collateral standard is to establish general requirements for protection against X-RADIATION in X-RAY EQUIPMENT, in order that the IRRADIATION of the human PATIENT, the OPERATOR, staff and members of the public can be kept as low as reasonably achievable, without jeopardizing the benefit of the RADIOLOGICAL procedure. Particular standards may specify their appropriate values and/or measures for general requirements specified in this collateral standard. The implementation of the general requirements or the reference to the particular standard instead, shall be justified in the RISK MANAGEMENT process. This collateral standard considers RADIATION PROTECTION aspects related to X-RADIATION only. Requirements for the control of the electrical energy used to generate X-RADIATION, which is also an important aspect of RADIATION PROTECTION, are included in IEC 60601-1 and in particular standards for the safety and ESSENTIAL PERFORMANCE of the EQUIPMENT concerned. —————————————————————————————————————– Préface CSA Ce document constitue la deuxième édition de la CAN/CSA-C22.2 nº 60601-1-3, Appareils électromédicaux – Partie 1-3 : Exigences générales pour la sécurité de base et les performances essentielles – Norme collatérale : Radioprotection dans les appareils à rayonnement X de diagnostic . Il s’agit de l’adoption, sans modifications, de la norme CEI (Commission Électrotechnique Internationale) 60601-1-3 (deuxième édition, 2008-01), qui porte le même titre. Cette norme remplace l’édition précédente publiée en 1998 qui portait la désignation CAN/CSA-C22.2 nº 601.1.3 (norme CEI/IEC 601-1-3:1994 adoptée). Cette norme fait partie d’une série de normes publiées par CSA lesquelles constituent le Code canadien de l’électricité, Deuxième partie. Cette norme est conçue pour être utilisée de concert avec la norme CAN/CSA-C22.2 nº 60601-1:08, Appareils électromédicaux — Partie 1 : Exigences générales pour la sécurité de base et les performances essentielles (norme IEC 60601-1:2005 adoptée, avec exigences propres au Canada). Cette norme est jugée convenable à l’évaluation de la conformité selon le domaine d’application établi dans la norme. Cette norme a été révisée en vue de son adoption pour le Canada par le Comité technique CSA sur les produits commerciaux et grand public, sous l’autorité du Comité directeur stratégique sur les exigences en matière de sécurité électricité, et a été officiellement approuvée par le Comité technique. Parce que cette norme touche à des concepts médicaux, elle a aussi été approuvée par le Comité technique CSA sur les installations électriques dans les établissements de santé, sous l’autorité du Comité directeur stratégique sur la technologie des soins de santé. Cette norme a été approuvée en tant que Norme nationale du Canada par le Conseil canadien des normes. Domaine d’application, objet et normes connexes 1.1 Domaine d’application La présente norme internationale s’applique à la SECURITE DE BASE et aux PERFORMANCES ESSENTIELLES des APPAREILS et des SYSTEMES ELECTROMEDICAUX, désignés ci-après sous le terme APPAREILS et SYSTEMES EM. La présente norme collatérale s’applique aux APPAREILS A RAYONNEMENT X et à leurs sousensembles, dont les IMAGES RADIOLOGIQUES d’un PATIENT humain sont utilisées à des fins de diagnostic, de planification ou de guide pour les procédures médicales. 1.2 Objet La présente Norme collatérale est destinée à spécifier des exigences générales qui viennent compléter celles de la norme générale et à servir de base pour les normes Particulières. L’objet de la présente norme collatérale est d’établir des exigences générales pour la protection contre les RAYONNEMENTS X dans les APPAREILS A RAYONNEMENT X, afin que l’IRRADIATION des PATIENTS humains, de l’OPERATEUR, des membres de l’équipe médicale et des autres personnes présentes puisse être maintenue à un niveau aussi bas que raisonnablement possible, sans compromettre le bénéfice de la procédure RADIOLOGIQUE. Des normes particulières peuvent spécifier des valeurs et/ou mesures qui leur sont appropriées par rapport aux exigences générales spécifiées dans la présente norme collatérale. La mise en oeuvre des exigences générales ou, à la place, la référence à la norme particulière doit être justifiée dans le processus DE GESTION DES RISQUES. La présente norme collatérale traite des aspects de RADIOPROTECTION liés aux RAYONNEMENTS X uniquement. Les exigences pour la commande de l’énergie électrique utilisée pour produire le RAYONNEMENT X, qui est aussi un aspect important de la RADIOPROTECTION, figurent dans la CEI 60601-1 et dans les normes particulières pour la sécurité et les PERFORMANCES ESSENTIELLES des APPAREILS concernés.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
121
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
CSA Preface This is the second edition of CAN/CSA-C22.2 No. 60601-1-3, Medical electrical equipment - Part 1-3: General requirements for basic safety and essential performance - Collateral Standard: Radiation protection in diagnostic X-ray equipment , which is an adoption without modification of the identically titled IEC (International Electrotechnical Commission) Standard 60601-1-3 (second edition, 2008-01). It supersedes the previous edition published in 1998 as CAN/CSA-C22.2 No. 601.1.3 (adopted CEI/IEC 601-1-3:1994). It is one in a series of Standards issued by CSA under Part II of the Canadian Electrical Code. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 60601-1:08, Medical electrical equipment — Part 1: General requirements for basic safety and essential performance (adopted IEC 60601-1:2005, with Canadian deviations). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on Consumer and Commercial Products, under the jurisdiction of the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. Due to the medical content of this Standard, it was also approved by the CSA Technical Committee on Applications of Electricity in Health Care under the jurisdiction of the Strategic Steering Committee on Health Care Technology. This Standard has been approved as a National Standard of Canada by the Standards Council of Canada. Scope, object and related standards 1.1 Scope This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL ELECTRICAL EQUIPMENT and MEDICAL ELECTRICAL SYSTEMS, hereafter referred to as ME EQUIPMENT and ME SYSTEMS. This collateral standard applies to X-RAY EQUIPMENT and to subassemblies of such equipment, where RADIOLOGICAL IMAGES of a human PATIENT are used for diagnosis, planning or guidance of medical procedures. 1.2 Object The object of this collateral standard is to specify general requirements that are in addition to those of the general standard and to serve as the basis for particular standards. The object of this collateral standard is to establish general requirements for protection against X-RADIATION in X-RAY EQUIPMENT, in order that the IRRADIATION of the human PATIENT, the OPERATOR, staff and members of the public can be kept as low as reasonably achievable, without jeopardizing the benefit of the RADIOLOGICAL procedure. Particular standards may specify their appropriate values and/or measures for general requirements specified in this collateral standard. The implementation of the general requirements or the reference to the particular standard instead, shall be justified in the RISK MANAGEMENT process. This collateral standard considers RADIATION PROTECTION aspects related to X-RADIATION only. Requirements for the control of the electrical energy used to generate X-RADIATION, which is also an important aspect of RADIATION PROTECTION, are included in IEC 60601-1 and in particular standards for the safety and ESSENTIAL PERFORMANCE of the EQUIPMENT concerned. ----------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue la deuxième édition de la CAN/CSA-C22.2 nº 60601-1-3, Appareils électromédicaux - Partie 1-3 : Exigences générales pour la sécurité de base et les performances essentielles - Norme collatérale : Radioprotection dans les appareils à rayonnement X de diagnostic . Il s'agit de l'adoption, sans modifications, de la norme CEI (Commission Électrotechnique Internationale) 60601-1-3 (deuxième édition, 2008-01), qui porte le même titre. Cette norme remplace l'édition précédente publiée en 1998 qui portait la désignation CAN/CSA-C22.2 nº 601.1.3 (norme CEI/IEC 601-1-3:1994 adoptée). Cette norme fait partie d'une série de normes publiées par CSA lesquelles constituent le Code canadien de l'électricité, Deuxième partie. Cette norme est conçue pour être utilisée de concert avec la norme CAN/CSA-C22.2 nº 60601-1:08, Appareils électromédicaux — Partie 1 : Exigences générales pour la sécurité de base et les performances essentielles (norme IEC 60601-1:2005 adoptée, avec exigences propres au Canada). Cette norme est jugée convenable à l’évaluation de la conformité selon le domaine d’application établi dans la norme. Cette norme a été révisée en vue de son adoption pour le Canada par le Comité technique CSA sur les produits commerciaux et grand public, sous l’autorité du Comité directeur stratégique sur les exigences en matière de sécurité électricité, et a été officiellement approuvée par le Comité technique. Parce que cette norme touche à des concepts médicaux, elle a aussi été approuvée par le Comité technique CSA sur les installations électriques dans les établissements de santé, sous l’autorité du Comité directeur stratégique sur la technologie des soins de santé. Cette norme a été approuvée en tant que Norme nationale du Canada par le Conseil canadien des normes. Domaine d'application, objet et normes connexes 1.1 Domaine d'application La présente norme internationale s'applique à la SECURITE DE BASE et aux PERFORMANCES ESSENTIELLES des APPAREILS et des SYSTEMES ELECTROMEDICAUX, désignés ci-après sous le terme APPAREILS et SYSTEMES EM. La présente norme collatérale s'applique aux APPAREILS A RAYONNEMENT X et à leurs sousensembles, dont les IMAGES RADIOLOGIQUES d'un PATIENT humain sont utilisées à des fins de diagnostic, de planification ou de guide pour les procédures médicales. 1.2 Objet La présente Norme collatérale est destinée à spécifier des exigences générales qui viennent compléter celles de la norme générale et à servir de base pour les normes Particulières. L'objet de la présente norme collatérale est d'établir des exigences générales pour la protection contre les RAYONNEMENTS X dans les APPAREILS A RAYONNEMENT X, afin que l'IRRADIATION des PATIENTS humains, de l'OPERATEUR, des membres de l'équipe médicale et des autres personnes présentes puisse être maintenue à un niveau aussi bas que raisonnablement possible, sans compromettre le bénéfice de la procédure RADIOLOGIQUE. Des normes particulières peuvent spécifier des valeurs et/ou mesures qui leur sont appropriées par rapport aux exigences générales spécifiées dans la présente norme collatérale. La mise en oeuvre des exigences générales ou, à la place, la référence à la norme particulière doit être justifiée dans le processus DE GESTION DES RISQUES. La présente norme collatérale traite des aspects de RADIOPROTECTION liés aux RAYONNEMENTS X uniquement. Les exigences pour la commande de l'énergie électrique utilisée pour produire le RAYONNEMENT X, qui est aussi un aspect important de la RADIOPROTECTION, figurent dans la CEI 60601-1 et dans les normes particulières pour la sécurité et les PERFORMANCES ESSENTIELLES des APPAREILS concernés.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CAN/CSA-E60730-2-9:18 (R2023)/A2:24 – Amendment 2:2024 to CAN/CSA-E60730-2-9:18, Automatic electrical controls — Part 2-9: Particular requirements for temperature sensing controls (Adopted amendment 2:2020 to IEC 60730-2-9:2018)
CDN $19.00 Add to cart -

CSA E61347-2-3:23 – Lamp control gear — Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps (Adopted IEC 61347-2-3:2011, edition 2:2011 consolidated with amendment 1:2016, with Canadian deviations) | Appareillages de lampes — Partie 2-3 : Exigences particulières pour les appareillages électroniques alimentés en courant alternatif et/ou en courant continu pour lampes fluorescentes (norme IEC 61347-2-3:2011 adoptée, édition 2:2011 consolidée par l’amendement 1:2016, avec exigences propres au Canada)
CDN $620.00 Add to cart -

CSA E61558-2-13:25 – Safety of transformers, reactors, power supply units and combinations thereof — Part 2-13: Particular requirements and tests for auto-transformers and power supply units incorporating auto-transformers for general applications (Adopted IEC 61558-2-13:2022, third edition, 2022-10, with Canadian deviations) | Sécurité des transformateurs, bobines d’inductance, blocs d’alimentation et combinaisons de ces éléments — Partie 2-13 : Exigences particulières et essais pour les autotransformateurs et les blocs d’alimentation qui incorporent des autotransformateurs pour applications d’ordre général (norme IEC 61558-2-13:2022 adoptée, troisième édition, 2022-10, avec exigences propres au Canada)
CDN $205.00 Add to cart -

CSA E60825-1:15 (R2025) – Safety of laser products — Part 1: Equipment classification and requirements (Adopted IEC 60825-1:2014, third edition, 2014-05, with Canadian deviations) | Sécurité des appareils à laser — Partie 1 : Classification des matériels et exigences (norme IEC 60825-1:2014 adoptée, troisième édition, 2014-05, avec exigences propres au Canada)
CDN $488.00 Add to cart







