ISO 16000:2009
ISO 16000:2009 Indoor air – Part 14: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) – Extraction, clean-up and analysis by high-resolution gas chromatography and mass spectrometry
CDN $351.00
Description
ISO 16000-14:2009 specifies extraction, clean-up, and analysis procedures for the determination of polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) collected from indoor air on particle filters backed by polyurethane foam (PUF). The method incorporates specific analyses by high resolution gas chromatography combined with high resolution mass spectrometry (HRGC/HRMS).
The method provides accurate quantitative data for tetra- to decachlorobiphenyls and tetra- to octachloro-dibenzo-p-dioxins/dibenzofurans (total concentrations for each isomeric series). It is capable of detecting 0,2 pg/m3 or lower concentrations of most PCBs and PCDFs/PCDDs with air sampling volumes up to 360 m3 or more in special cases. However, it may not be possible to detect all analytes at 0,2 pg/m3 or lower, especially at lower sampling volumes.
Precision under normal conditions can be expected to be ±25 % or better and uncertainty ±50 % or better.
Edition
1
Published Date
2009-05-15
Status
PUBLISHED
Pages
53
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment

Abstract
ISO 16000-14:2009 specifies extraction, clean-up, and analysis procedures for the determination of polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) collected from indoor air on particle filters backed by polyurethane foam (PUF). The method incorporates specific analyses by high resolution gas chromatography combined with high resolution mass spectrometry (HRGC/HRMS).
The method provides accurate quantitative data for tetra- to decachlorobiphenyls and tetra- to octachloro-dibenzo-p-dioxins/dibenzofurans (total concentrations for each isomeric series). It is capable of detecting 0,2 pg/m3 or lower concentrations of most PCBs and PCDFs/PCDDs with air sampling volumes up to 360 m3 or more in special cases. However, it may not be possible to detect all analytes at 0,2 pg/m3 or lower, especially at lower sampling volumes.
Precision under normal conditions can be expected to be ±25 % or better and uncertainty ±50 % or better.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-
ISO 16000:2024 Indoor air – Part 11: Determination of the emission of volatile organic compounds from samples of building products and furnishing – Sampling, storage of samples and preparation of test specimens
0 out of 5CDN $173.00 Add to cart -
ISO 16000:2024 Indoor air – Part 33: Determination of phthalates with gas chromatography/mass spectrometry (GC/MS)
0 out of 5CDN $312.00 Add to cart -
ISO 16000:2025 Indoor air – Part 43: Standard method for assessing the reduction rate of culturable airborne fungi by air purifiers using a test chamber
0 out of 5CDN $173.00 Add to cart -
ISO 16000:2024 Indoor air – Part 9: Determination of the emission of volatile organic compounds from samples of building products and furnishing – Emission test chamber method
0 out of 5CDN $173.00 Add to cart