REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

API RP 1173: Pipeline Safety Management Systems

$

167

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 1173: Pipeline Safety Management Systems : Errata 1

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 11S2: Electric Submersible Pump Testing: Edition 3

$

158

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 14L: Lock Mandrels and Landing Nipples : Reaffirmed

$

273

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 20F: Corrosion Resistant Bolting for Use in the Petroleum and Natural Gas Industries : Reaffirmed

$

169

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 5NCL Nickel Content Limits for API 5CT Sour Service Products

$

149

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 19ICD: Inflow Control Devices : Reaffirmed

$

189

BUY NOW

ISO 21439:2009

ISO 21439:2009 Clinical dosimetry – Beta radiation sources for brachytherapy

CDN $390.00

SKU: d2da28a0eaa3 Categories: ,

Description

ISO 21439:2009 specifies methods for the determination of absorbed-dose distributions in water or tissue that are required prior to initiating procedures for the application of beta radiation in ophthalmic tumour and intravascular brachytherapy]. Recommendations are given for beta-radiation source calibration, dosemetry measurements, dose calculation, dosemetric quality assurance, as well as for beta-radiation brachytherapy treatment planning. Guidance is also given for estimating the uncertainty of the absorbed dose to water. ISO 21439:2009 is applicable to “sealed” radioactive sources, such as plane and concave surface sources, source trains of single seeds, line sources, shell and volume sources, for which only the beta radiation emitted is of therapeutic relevance.

The standardization of procedures in clinical dosemetry described in ISO 21439:2009 serves as a basis for the reliable application of beta-radiation brachytherapy. The specific dosemetric methods described in ISO 21439:2009 apply to sources for the curative treatment of ophthalmic disease, for intravascular brachytherapy treatment, for overcoming the problem of restenosis and for other clinical applications using beta radiation.

ISO 21439:2009 is geared towards organizations wishing to establish reference methods in dosemetry aiming at clinical demands for an appropriately small uncertainty of the delivered dose. ISO 21439:2009 does not exclude the possibility that there can be other methods leading to the same or smaller measurement uncertainties.

Edition

1

Published Date

2009-01-29

Status

PUBLISHED

Pages

92

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 21439:2009 specifies methods for the determination of absorbed-dose distributions in water or tissue that are required prior to initiating procedures for the application of beta radiation in ophthalmic tumour and intravascular brachytherapy]. Recommendations are given for beta-radiation source calibration, dosemetry measurements, dose calculation, dosemetric quality assurance, as well as for beta-radiation brachytherapy treatment planning. Guidance is also given for estimating the uncertainty of the absorbed dose to water. ISO 21439:2009 is applicable to “sealed” radioactive sources, such as plane and concave surface sources, source trains of single seeds, line sources, shell and volume sources, for which only the beta radiation emitted is of therapeutic relevance.

The standardization of procedures in clinical dosemetry described in ISO 21439:2009 serves as a basis for the reliable application of beta-radiation brachytherapy. The specific dosemetric methods described in ISO 21439:2009 apply to sources for the curative treatment of ophthalmic disease, for intravascular brachytherapy treatment, for overcoming the problem of restenosis and for other clinical applications using beta radiation.

ISO 21439:2009 is geared towards organizations wishing to establish reference methods in dosemetry aiming at clinical demands for an appropriately small uncertainty of the delivered dose. ISO 21439:2009 does not exclude the possibility that there can be other methods leading to the same or smaller measurement uncertainties.

Previous Editions

Can’t find what you are looking for?

Please contact us at: