REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

API STD 668: Brazed Aluminum Plate-fin Heat Exchangers for General Refinery Services

$

386

BUY NOW

Placeholder headline

This is just a placeholder headline

MSS SP-134-2025: Valves for Cryogenic Service, including Requirements for Body/Bonnet Extensions

$

315

BUY NOW

Placeholder headline

This is just a placeholder headline

MSS SP-150-2025: Valves for Use in Hydrogen Peroxide Service

$

189

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 673: Centrifugal Fans for Petroleum, Chemical and Gas Industry Services: Edition 3

$

300

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 674: Positive Displacement Pumps-Reciprocating: 3rd Edition

$

363

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 22.3: Testing Protocol for Flare Gas Metering: Edition 2

$

193

BUY NOW

ISO 23973:2020

ISO 23973:2020 Liquid chromatography at critical conditions (LCCC) – Chemical heterogeneity of polyethylene oxides

CDN $312.00

SKU: 387133ec1f8b Category:

Description

This document establishes a valid method for separation of chemically heterogeneous polyethylene oxide (PEO) mixtures and for the determination the number and content of the chemically heterogeneous species in the overall sample.

The method presented in this document serves as a technical guideline and enables laboratories to learn the principle of “critical chromatography” on a validated system.

This method presented in this document with its stated system parameters is not applicable for other polymer classes, due to the diversity of the interactions between the polymer/mobile phase/stationary phase and the number of separation systems that are therefore available.

The evaluation of the interlaboratory testing has shown that many error sources relate to the technique of liquid chromatography in general. Possible error sources are described in Annex A.

Details on the evaluation of the interlaboratory testing are given in Annex B.

Elugrams of the participants (excerpts) are given in Annex C.

Investigations of the long-term stability of the test mixture are given in Annex D.

Edition

1

Published Date

2020-08-17

Status

PUBLISHED

Pages

49

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document establishes a valid method for separation of chemically heterogeneous polyethylene oxide (PEO) mixtures and for the determination the number and content of the chemically heterogeneous species in the overall sample.

The method presented in this document serves as a technical guideline and enables laboratories to learn the principle of "critical chromatography" on a validated system.

This method presented in this document with its stated system parameters is not applicable for other polymer classes, due to the diversity of the interactions between the polymer/mobile phase/stationary phase and the number of separation systems that are therefore available.

The evaluation of the interlaboratory testing has shown that many error sources relate to the technique of liquid chromatography in general. Possible error sources are described in Annex A.

Details on the evaluation of the interlaboratory testing are given in Annex B.

Elugrams of the participants (excerpts) are given in Annex C.

Investigations of the long-term stability of the test mixture are given in Annex D.

Previous Editions

Can’t find what you are looking for?

Please contact us at: