Your cart is currently empty!

ISO 27891:2015
ISO 27891:2015 Aerosol particle number concentration – Calibration of condensation particle counters
CDN $390.00
Description
ISO 27891:2015 describes methods to determine the detection efficiency of condensation particle counters (CPCs) at particle number concentrations ranging between 1 cm-3 and 105 cm-3, together with the associated measurement uncertainty. In general, the detection efficiency will depend on the particle number concentration, the particle size, and the particle composition. The particle sizes covered by the methods described in this International Standard range from approximately 5 nm to 1 000 nm.
The methods can therefore be used both to determine a CPC calibration factor to be applied across the range of larger particle sizes where the detection efficiency is relatively constant (the plateau efficiency), and to characterize the drop in CPC detection efficiency at small particle sizes, near the lower detection limit. These parameters are described in more detail in Annex A.
The methods are suitable for CPCs whose inlet flows are between approximately 0,1 l/min and 5 l/min.
This International Standard describes a method for estimating the uncertainty of a CPC calibration performed according to this International Standard.
Edition
1
Published Date
2015-02-27
Status
PUBLISHED
Pages
119
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment

Abstract
ISO 27891:2015 describes methods to determine the detection efficiency of condensation particle counters (CPCs) at particle number concentrations ranging between 1 cm-3 and 105 cm-3, together with the associated measurement uncertainty. In general, the detection efficiency will depend on the particle number concentration, the particle size, and the particle composition. The particle sizes covered by the methods described in this International Standard range from approximately 5 nm to 1 000 nm.
The methods can therefore be used both to determine a CPC calibration factor to be applied across the range of larger particle sizes where the detection efficiency is relatively constant (the plateau efficiency), and to characterize the drop in CPC detection efficiency at small particle sizes, near the lower detection limit. These parameters are described in more detail in Annex A.
The methods are suitable for CPCs whose inlet flows are between approximately 0,1 l/min and 5 l/min.
This International Standard describes a method for estimating the uncertainty of a CPC calibration performed according to this International Standard.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-
ISO 13317:2014 Determination of particle size distribution by gravitational liquid sedimentation methods – Part 4: Balance method
0 out of 5CDN $173.00 Add to cart -
ISO 9284:2013 Abrasive grains – Test-sieving machines
0 out of 5CDN $76.00 Add to cart -
ISO 19996:2024 Charge conditioning of aerosol particles for particle characterization and the generation of calibration and test aerosols
0 out of 5CDN $351.00 Add to cart -
ISO 13320:2020 Particle size analysis – Laser diffraction methods
0 out of 5CDN $351.00 Add to cart